en - Technical data
37
Voltage versions and electrical data
Standard:
Convertible to:
Supply voltage
3N AC 380-415V
3N AC 380-415V
Frequency
50 Hz
60 Hz
Power rating
4,3 kW
4,3 kW
Fuse rating (on site)
3 x 16 A
3 x 16 A
Connection cable, min. cross-section
4 x 1,5 mm²
4 x 1,5 mm²
Cable gland
M16 x 1,5 mm
M16 x 1,5 mm
Supply voltage
3 AC 400V
Frequency
60 Hz
Power rating
4,3 kW
Fuse rating (on site)
3 x 16 A
Connection cable, min. cross-section
4 x 1,5 mm²
Cable gland
M16 x 1,5 mm
Miele recommends connecting the machine via a wall socket with an all-pole means of deactivation and interlock in accordance with
IEC 60309 and IEC 60947 so that electrical safety checks can be carried out easily.
For hard-wired machines, an isolator in accordance with IEC 60947 must be installed.
The wall socket or isolator must remain accessible at all times once the machine has been installed.
To increase safety, Miele recommends installation of a residual current device (RCD). Only use residual current devices that are
sensitive to universal current (type B).
Connection for equipotential bonding
Connection with male thread (machine)
10 mm x 30 mm (3/8" x 1 3/16")
Size of washers and nuts
M 10
An equipotential bond with good contact connection must always be provided in accordance with all national and local regulations.
Steam connection
Indirect steam heating
Steam overpressure
400–1000 kPa
Boiling point
152–184 °C
Heater rating (peak capacity)
50 kW
Mass flow (peak capacity)
84 kg/h
Threaded union (on site)
½
" female thread
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
Direct steam heating
Steam overpressure (high pressure)
≤
400 kPa
Boiling point (high pressure)
≤
152 °C
Heater rating (peak capacity high pressure)
86 kW
Mass flow (peak capacity high pressure)
140 kg/h
Steam overpressure (low pressure)
≤
50 kPa
Boiling point (low pressure)
≤
120 °C
Heater rating (peak capacity low pressure)
29 kW
Heater rating (peak capacity low pressure)
45 kg/h
Threaded union (on site)
¾
" female thread
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
Содержание PW 6321 D
Страница 2: ...2 de 4 en 23 fr 41 es 59 ru 78 it 96 ...
Страница 17: ...de Aufstellung INSTALLATION 17 Abmessungen Maßangaben in Millimeter ...
Страница 35: ...en Installation INSTALLATION 35 Dimensions Dimensions in mm ...
Страница 53: ...fr Installation INSTALLATION 53 Dimensions Dimensions en millimètres ...
Страница 72: ...es Emplazamiento INSTALLATION 72 Medidas Medidas en milímetros ...
Страница 91: ...ru Установка INSTALLATION 91 ...
Страница 108: ...it Posizionamento INSTALLATION 108 Misure Misure in millimetri ...