Installation plan PW 6131 Steam
Date 19.10.2007
Page
8
USA CDN
Indirect steam (page 4)
Steam pressure
87 - 145 psi
87 - 145 psi
Steam pressure on dryer version
58 - 72 psi
58 - 72 psi
Boiling point
306 - 363 °F
152 - 184 °C
Heating capacity
37 kW
37 kW
Steam
connection
Steam supply capacity
147 lbs/h
67 kg/h
Connection thread (on-site)
1/2" MPT
1/2" MPT
Steam valve, steam filter and steam faucet must be
provided on-site.
Direct steam (page 5)
Steam pressure (High pressure)
≤
58 psi
≤
58 psi
Boiling point (High pressure)
≤
306 °F
≤
152 °C
Heating capacity (High pressure)
26 kW
26 kW
Steam supply capacity (High pressure)
101 lbs/h
46 kg/h
Steam pressure (Low pressure)
≤
7.25 psi
≤
7,25 psi
Boiling point (Low pressure)
≤
84 °F
≤
120 °C
Heating capacity (Low pressure)
18 kW
18 kW
Steam supply capacity (Low pressure)
68 lbs/h
31 kg/h
Connection thread (on-site)
1/2" MPT
1/2" MPT
Steam valve, steam filter, steam faucet and non-return
valve must be provided on-site.
Note installation instructions for steam-heated Miele
washer-extractors.
Condensate
connection
Indirect steam (page 4)
Connection thread (on-site)
1/2" MPT
1/2" MPT
Steam valve, steam filter and steam faucet must be
provided on-site.
Min. flow pressure
14.5 psi
14,5 psi
Max. pressure
145 psi
145 psi
Cold water
(Soft water)
Max. throughput (if hot water supply is not available)
6.9 (11) gal/min
26 (42) l/min
On-site connection thread
3/4" MPT
3/4" MPT
Length of connection hose
(supplied: 2 hoses and Y adapter)
59 1/16"
1.500 mm
Water requirements (average 140°F [60°C] program)
Standard connection (with hot water connection)
27.5 gal/h
approx. 104 l/h
Additional requirements if hot water supply is not
available.
Max. temperature
158 °F
70 °C
Min. flow pressure
14.5 psi
14,5 psi
Hot water
Max. pressure
145 psi
145 psi
Max. throughput
4.2 gal/min
16 l/min
On-site connection thread
3/4" MPT
3/4" MPT
Length of connection hose (supplied)
59 1/16"
1.500 mm
Water requirements (average for 140°F [60°C] program)
Standard connection (with hot water connection)
approx. 30 gal/h
approx. 98 l/h
If no hot water supply, connect hose to cold water!
Min. flow pressure
14.5 psi
14,5 psi
Max. pressure
145 psi
145 psi
Max. throughput
8.45 gal/min
32 l/min
Mains water
(Raw water)
(Optional)
On-site connection thread
3/4" MPT
3/4" MPT
Length of connection hose
(supplied: 2 hoses and Y adapter)
59 1/16"
1.500 mm
Water requirements (average for 140°F [60°C] program)
Standard connection (with hot water connection)
approx. 16.4 gal/h
approx. 62 l/h
If connected to raw water supply, subtract cold water
(soft) volume.
If no raw water supply, connect hose to cold water!