Cold water
(Soft water)
Min. flow pressure
14.5 psi
100 kPa
Max. pressure
145 psi
1000 kPa
Max. throughput
2.9 gal/min
11 l/min
On-site connection thread
¾" garden hose
thread, male
¾" garden hose
thread, male
Length of connection hose (supplied: 1 connection hose)
61“
1550 mm
Hourly water demand (average for 60°C program) for
standard connection (with hot
and
cold water)
approx. 18.5
gal/h
approx. 70 l/h
If hot water supply is not available add hot water demand to
cold water demand.
Warm water
(Soft water)
Max. temperature
158°F
70°C
Min. flow pressure
14.5 psi
100 kPa
Max. pressure
145 psi
1000 kPa
Max. throughput
2.9 gal/min
11 l/min
On-site connection thread
¾" garden hose
thread, male
¾" garden hose
thread, male
Length of connection hose
(supplied: 1 connection hose)
61“
1550 mm
Hourly water demand (average for 60°C program)
approx.
18.5 gal/h
approx. 70L/h
Machine can be connected to a hot water supply line with a
temperature of 70°C to max. 85°C. This requires a separate
inlet hose. This additional inlet hose is available from Miele
Spares. The machine must also be reprogrammed by Miele
Service.
If hot water is not available, connect hot water hose to cold
water valve!
Drain: Dump
valve
Max. temperature
158°F
70°C
Machine-side drain connection (ext. diameter)
2 15/16“
75 [DN 70] mm
On-site drain (int. diameter)
2 15/16“
75 [DN 70] mm
Max. transient throughput
16.4 gal/min
62 l/min
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
Fittings for
base/floor
installation
Miele base UG/UO 5010
4 × metal angled brackets
(to secure machine to base )
4 × screws DIN 571 (Ø × length)
5/16“ x 2 9/16“
8 x 65 mm
4 × rawl plugs (Ø × length)
½“ x 2 3/8“
12 x 60 mm
Machine must be bolted to the base and floor!
Fixing materials for a floating screed floor are to be provided
on site.
Installation on floor or concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
¼“ x 2“
6 x 50 mm
2 × rawl plugs (Ø × length)
5/16“ x 1 9/16“
8 x 40 mm
Machine must be bolted to the base or floor. Fittings are
supplied with machine
Fixing materials for a floating screed floor are to be provided
on site.
AV
Technical datasheet: PW5105 EL AV (Dump valve)
Date: 01.2015
Page: 12