Installation
29
a
Extraction
b
Recirculation
c
Ventilation grille positioned at the top for recirculation
de
(Only
d
is required for recirculation mode cooker hoods). The shaded area
represents the wall or ceiling area for the ducting cut-out and for the connec-
tion socket. Recirculation cooker hoods only need a connection socket to be
fitted.
Connection for air extraction
150 mm, or
125 mm with reducing collar.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Minimum distance S
Electric hob
450 mm
Electric grill, deep fat fryer (electric)
650 mm
Multi-burner gas hob,
total output
≤
12.6 kW, no burner
>
4.5 kW
650 mm
Multi-burner gas hob,
total output
>
12.6 kW and
≤
21.6 kW,
no burner
>
4.8 kW.
760 mm
Multi-burner gas hob,
total output
>
21.6 kW,
or multi-burner gas hob where one burner
>
4.8 kW.
Not possible
Single burner gas hob, output
≤
6 kW.
650 mm
Single burner gas hob, output
>
6 kW and
≤
8.1 kW.
760 mm
Single burner gas hob, output
>
8.1 kW
Not possible
Содержание PUR 68 W
Страница 3: ...Contents 3 Technical data 36 ...
Страница 14: ...Guide to the appliance 14 ...
Страница 26: ...Installation 26 Assembly parts ...
Страница 28: ...Installation 28 Appliance dimensions The diagram is not drawn to scale ...
Страница 40: ...M Nr 10 480 140 00 en GB PUR 68 W PUR 98 W ...