Fittings
(supplied)
Without base
2 × clamps
2 × screws DIN 571 (Ø × length)
1/4''
x 1 9/16
''
6
mm
x
40 mm
2 × rawl plugs (Ø × length)
3/8
''
x 2
''
10
mm
x
50 mm
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
On concrete base
2 × clamps
2 × screws DIN 571 (Ø × length)
1/4''
x 1 9/16
''
6
mm
× 40 mm
2 × rawl plugs (Ø × length)
3/8
''
x 2
''
10
mm
× 50 mm
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Unit width
47
1/2''
1206 mm
Machine depth
40 1/16
''
1018 mm
Unit height
64 9/16
''
1640 mm
Casing width
47
1/4''
1200 mm
Casing depth
35 15/16
''
913 mm
Minimum width of delivery access to installation site
40 9/16
''
1030 mm
Recommended rear wall gap (measured to front of machine) 63
''
1600 mm
Min. wall gap (to rear edge of lid)
19 11/16
''
500 mm
58
4
lb
265 kg
2968 N
2968 N
3071 BTU/h
0.9kW
72.2 dB (A)
72.2 dB (A)
Net weight
Dynamic floor load, max.
Average heat dissipation
(dependent on ambient room temperature and program
selected)
Noise level
Sound pressure level
(measured at a distance of
39 3/8'' [
1 m
]
from the
machine and at a height of
63''
[
1.6 m
])
60 dB (A)
60 dB (A)
Installation should only be carried out by authorized
technicians
in accordance with
national
regulations!
Follow
installation
instructions when installing machine! All rights reserved!
Installation plan: PT 8507 D (
S
team
Heated
)
Date: 2015
-06-02
Page: 15
Содержание PT 8507 D
Страница 1: ...Installation Plan Tumble dryer PT 8507 D Steam Heated en US 05 15 M Nr 10 027 130 00 ...
Страница 4: ... 40 1 8 47 1 4 47 1 2 36 63 2 5 7 8 6 1 4 6 3 8 PT 8507 D measurements in inches 4 ...
Страница 8: ...PT 8507 D measurements in millimeters 8 ...
Страница 9: ... PT 8507 D measurements in millimeters 9 ...
Страница 10: ...PT 8507 D measurements in millimeters 10 ...
Страница 11: ...PT 8507 D measurements in millimeters 11 ...
Страница 12: ...PT 8507 D measurements in millimeters 12 ...