Supervisor level
87
External applications
External exhaust flap
External hardware is connected via the
Miele XCI box.
The time delay between the external
exhaust air flap's activation point and
the switch-on time for the drum/fan
motor is regulated.
A message appears in the display while
the exhaust air flap is open.
– Factory setting: Off
This option must always be selected
if there is no exhaust air flap to
activate. This prevents the
programme from being cancelled.
– On
- 0 seconds
- 1 second
- 2 seconds
...
- 300 seconds
Additional fan
External hardware is connected via the
Miele XCI box.
If an extra fan is connected, it must be
switched on at the same time as the
drive unit.
– Off
– On
Pressure sensor
External hardware is connected via the
Miele XCI box.
When using a shared exhaust air duct,
one tumble dryer may have to be
switched off or suppressed from the
outset if certain pressure levels have
built up in the ducting. Because the
pressure sensor is an external unit,
there is the option to add both a
normally open contact or a normally
closed contact.
A message appears in the display while
the exhaust air flap is open.
– Off = Not active
–
Normally open contact
= Active
Responds to
high potential
–
Norm. closed contact
= Active
Responds to
low potential