. . . with partition
The minimum thickness of the partition
is
5
/
8
" (16 mm).
If there is a partition between the
adjacent appliances, then each
appliance is to be individually installed
within its own niche.
A heating mat must only be installed if
the partition wall is less than 6"
(160 mm) wide:
For instructions on how to install the
heating mat please refer to the
instructions included in the "Merging
Kit".
The "Merging Kit" can be obtained
from Miele.
Side panels
If one side of the appliance is visible, a
side panel must be used.
The side panel must be firmly secured
to the wall, the floor and the overhead
furniture/fixtures before the appliance is
placed in the cavity.
The dimensions of the side panel are
taken from the opposite wall of the
installation space. During installation,
ensure that the cavity is square and the
measurements are correct.
Installation
38
Содержание KWT 1601 SF
Страница 32: ...32 ...
Страница 39: ...Door dimensions open min 90 A KWT 16x1 SF 26 5 8 677 mm A KWT 16x1 SF 12 305 mm 1 Power supply Dimensions 39 ...
Страница 40: ...Niche dimensions A B KWT 16x1 SF 24 1 2 622 2 mm 24 610 mm Dimensions 40 ...