![Miele KMR1124 G Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/miele/kmr1124-g/kmr1124-g_operating-and-installation-instructions_234441041.webp)
Dimensional drawings
41
All rangetops with Standard Burner Configuration
In case of combustible construction, an additional minimum clearance of
6" (150 mm) on each side is necessary. Ensure local codes are observed.
Position
Dimensions
Description
13" (330 mm)
Maximum depth of top cabinet
18" (457 mm)
Minimum distance to bottom edge of
top cabinet
7¹/₂" (190.5 mm)
Distance between the top edge of the
countertop and the top edge of the
support base
10" (254 mm)
Minimum distance to combustible sur-
faces
Support base
1)
1) The support base must have a minimum thickness of ³/₄" (19.05 mm).
At the rear right of the support base, a cut-out of 5 1/8" x 7 1/8" (130 mm x 80 mm) (gas
connection) is provided, and, at the rear left, a cut-out of 4 6/8" x 1 9/16" (120 mm x 40
mm) (electrical connection).