Miele KM 7464 FL Скачать руководство пользователя страница 22

11271160-03

Installation

*INSTALLATION*

Wiring diagram

L1

200-240 V~

200-240 V~

200-240 V~

a b c d e

-

L2

L3

N

-

L2

b

L1

a

c d

N

e

(L3)

200-240 V~

200-240 V~

a

L1

b c d

N

e

-

(L2)

200-240 V~

Содержание KM 7464 FL

Страница 1: ...er or laminate coatings of worktops or adjacent kitchen units must be treated with 100 C heat resistant adhesive which will not dissolve or distort Any backmoulds must be of heat resistant material The hob must not be installed over a fridge fridge freezer freezer dishwasher washing machine washer dryer or tumble dryer This hob must not be installed above ovens or cookers unless these have a built...

Страница 2: ...be maintained between the hob and the cooker hood above it If combustible objects are installed above the hob e g cabinets utensil rail etc a minimum safety distance of 600 mm must be maintained When two or more appliances which have different safety distances are installed together below a cooker hood you should observe the greatest specified safety distance ...

Страница 3: ... shown below must be maintained between a tall unit or a wall to the left or right of the hob with a minimum distance of 300 mm on the opposite side Minimum distance between the back of the worktop cut out and the rear edge of the worktop 50 mm Minimum distance between the worktop cut out and a wall or tall unit to the right of it 50 mm Minimum distance between the worktop cut out and a wall or ta...

Страница 4: ...erside of the hob and Upper edge of oven 15 mm Upper edge of intermediate shelf 15 mm Upper edge of drawer 5 mm Base of drawer 75 mm Intermediate shelf It is not necessary to fit an intermediate shelf underneath the hob but one may be fitted if you wish Leave a gap of 10 mm at the back between the cabinet and the intermediate shelf to accommodate the power cable A gap of 20 mm is recommended at th...

Страница 5: ...between the cut out and the cladding If the niche cladding is made from a non combustible material e g metal natural stone ceramic tiles the minimum safety distance between the cut out and the cladding will be 50 mm less the thickness of the cladding Example 15 mm niche cladding 50 mm 15 mm minimum safety distance of 35 mm Flush fitted hobs Hob with frame or bevelled edge a Masonry b Niche claddin...

Страница 6: ... the hob ever needs to be removed for servicing Do not use sealant between the hob and the worktop The sealing strip under the edge of the hob provides a sufficient seal for the worktop Tiled worktops Grout lines and the hatched area underneath the hob frame must be smooth and even If they are not the hob will not sit flush with the worktop and the sealing strip underneath the hob will not provide...

Страница 7: ...t so that the hob is easily accessible from underneath after installation and the bottom half of the casing can be removed for maintenance If the underside of the hob is not freely accessible after installation any sealant used to plug the gaps around the appliance must be removed to enable the hob to be lifted out of the cut out should this be necessary Natural stone worktops The hob is set direc...

Страница 8: ...271160 03 Installation INSTALLATION Installation dimensions Surface mounted All dimensions are given in mm KM 7464 FR a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose ...

Страница 9: ...11271160 03 Installation INSTALLATION KM 7465 FR a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose ...

Страница 10: ...11271160 03 Installation INSTALLATION KM 7464 FL KM 7465 FL a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose ...

Страница 11: ...11271160 03 Installation INSTALLATION KM 7474 FR a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose ...

Страница 12: ...11271160 03 Installation INSTALLATION KM 7474 FL a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose ...

Страница 13: ...om incorrect connection The hob electronics may be damaged if a short circuit occurs The power cable must be connected to the hob by a qualified electrician Connect the power cable by following the instructions in the wiring diagram on the hob see Installation Electrical connection Feed the power cable for the hob down through the worktop cut out Place the hob centrally in the cut out When doing t...

Страница 14: ...N Installation dimensions Flush fit All dimensions are given in mm KM 7404 FX a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose c Stepped cut out natural stone worktop d Wooden batten 13 mm not supplied ...

Страница 15: ...1160 03 Installation INSTALLATION KM 7414 FX a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose c Stepped cut out natural stone worktop d Wooden batten 13 mm not supplied ...

Страница 16: ...0 03 Installation INSTALLATION KM 7414 FX Glass a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose c Stepped cut out natural stone worktop d Wooden batten 13 mm not supplied ...

Страница 17: ...03 Installation INSTALLATION KM 7464 FL KM 7465 FL a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose c Stepped cut out natural stone worktop d Wooden batten 12 mm not supplied ...

Страница 18: ...1160 03 Installation INSTALLATION KM 7474 FL a Front b Mains connection box The mains connection cable L 1440 mm is supplied loose c Stepped cut out natural stone worktop d Wooden batten 12 mm not supplied ...

Страница 19: ...ed sealing strip under the edge of the hob Do not apply the sealing strip under tension The sealing strip is not required for the following models KM 7404 FX KM 7414 FX KM 7414 FX Glas Feed the power cable for the hob down through the worktop cut out Centre the hob in the cut out The gap between the ceramic surface and the worktop must be at least 2 mm wide This is required so that the hob can be ...

Страница 20: ...nd comply with the national regulations and any additional regulations of the local electricity provider After installation ensure that all electrical components are shielded and cannot be accessed by users Total power rating See data plate Connection data The connection data is quoted on the data plate Please ensure these match the household mains supply Please see wiring diagrams for connection ...

Страница 21: ...east type B or C Switch the lever from 1 on to 0 off Residual current device RCD Switch the main switch from 1 on to 0 off or press the test button Mains connection cable The hob must be connected to the electrical supply with a special connection cable type H 05 VV F PVC insulated with a suitable diameter Please see wiring diagram for connection See the data plate on the hob for the correct volta...

Страница 22: ...11271160 03 Installation INSTALLATION Wiring diagram L1 200 240 V 200 240 V 200 240 V a b c d e L2 L3 N L2 b L1 a c d N e L3 200 240 V 200 240 V a L1 b c d N e L2 200 240 V ...