To convert the burners
Turn off the main gas supply (if the appliance has already been installed) and
disconnect it from the main electrical power supply before proceeding.
The following orifices and needle valves should be installed into their respective
burners.
Conversion table
Code
Orifice size
(Ø mm)
Code
Needle valve size
(Ø mm)
Natural gas (NG)
Auxiliary burner
105
1.05
44
0.44
Normal burner
115
1.15
52
0.52
Fast burner
150
1.50
62
0.62
Wok burner
inner
outer
76
180
0.76
1.80
40
88
0.40
0.88
Propane (LP)
Auxiliary burner
68
0.68
25
0.25
Normal burner
72
0.72
32
0.32
Fast burner
92
0.92
40
0.40
Wok burner
inner
outer
37
105
0.37
1.05
25
54
0.25
0.54
Save the orifices and needle valves removed from the appliance for future use.
Converting to another type of gas