Risk of explosion due to an in-
correct conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an approved and registered gas in-
staller in strict accordance with cur-
rent local and national safety and
building regulations (GasSafe in the
UK). The installer is responsible for
ensuring that the appliance functions
correctly when installed.
When converting to another type of
gas, both the main
and
small jets
need to be changed.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Burner
Main jet
Small jet
Natural gas H
Small
0.69
0.39
Medium
0.95
0.42
Large
1.10
0.54
Wok
1.35
0.80
Liquid gas
Small
0.50
0.27
Medium
0.65
0.32
Large
0.78
0.40
Wok
0.98
0.54