To avoid a hazard due to instability
of the appliance, it must be fixed in
accordance with the instructions.
Location
The appliance should be installed in a
dry, well-ventilated room.
The room temperature should not go
above or below the climate range for
which the appliance is designed.
The higher the ambient temperature of
the room, the more energy the
appliance requires to operate.
It should not be installed where it is
exposed to direct sunlight or directly
adjacent to a heat-producing appliance
such as an oven or a radiator.
Important: tropical / humid
environments
During periods of high humidity,
some condensation may appear on
outside surfaces of cooling
appliances. This condensation will
disappear when humidity levels
drop. For prevention, it is advisable
to install the appliance with sufficient
ventilation in a dry and/or an
air-conditioned room.
Please ensure that doors are closing
and sealing properly.
Please ensure that the appliance is
installed in accordance with these
installation instructions and that the
handle is fitted correctly. Should you
require further assistance please
contact your Miele customer service
centre.
Climate range
The appliance is designed for use
within certain climate ranges (ambient
temperatures), and should not be used
outside this range. The climate range of
the appliance is stated on the data
plate inside the appliance.
Climate range
Ambient room
temperature
SN
N
ST
T
SN-ST
SN-T
+10°C to +32°C
+16°C to +32°C
+16°C to +38°C
+16°C to +43°C
+10°C to +38°C
+10°C to +43°C
Operating in a room which is too cold
will cause the cooling system to switch
off for too long, causing the internal
temperature in the appliance to rise
with the risk of food deteriorating and
going off.
Ventilation
Air at the back of the appliance gets
warm. The appliance housing unit must
be constructed to allow sufficient space
for ventilation.
A ventilation gap of at least 38 mm
depth must be allowed for behind the
appliance for air to circulate.
The air inlet to the appliance is via the
plinth in the housing unit.
The cross-section of the air inlet and
outlet must be at least 200 cm
2
to
ensure that air can circulate without
hindrance. Otherwise the appliance has
to work harder, resulting in an increase
in electricity consumption.
Installation
32
Содержание K 9252 i
Страница 34: ...Niche height mm A K 9252 i 1 874 890 Building in dimensions 34 ...
Страница 47: ...47 ...
Страница 48: ...Alteration rights reserved 1309 K 9252 i 1 M Nr 07 469 651 00 ...