Important
If the exhaust ducting is to run through
rooms, ceiling space etc., where there
may be great variations in temperature
between the different areas, the prob-
lem of sweating or condensation will
need to be addressed.
The exhaust ducting will need to be
suitably insulated.
Condensate trap
In addition to insulating the exhaust
ducting we recommend that a suitable
condensate trap is also installed to col-
lect and evaporate any condensate
which may occur.
When installing a condensate trap en-
sure that it is located vertically and if
possible directly above the exhaust
connection.
Installation - extraction
25