manualshive.com logo in svg
background image

Operating and Installation Instructions

..............................................................................................................................

Cooker Hoods

DIA   1076-2            DIA   1076-2 EX 

DIA   1070-2            DIA   1070-2 EX 

Q

Содержание Imperial DIA 1070-2

Страница 1: ...Operating and Installation Instructions Cooker Hoods DIA 1076 2 DIA 1076 2 EX DIA 1070 2 DIA 1070 2 EX Q ...

Страница 2: ... 10 Switching off 11 Switching the lighting on or off 11 Filter operating time counter 12 Reading the filter operating time counter 12 Altering the filter operating time counter 13 Cleaning and care Housing 14 Changing a halogen light bulb 16 After sales service 17 Electrical connection 18 Installation 19 Glass panels 23 Installation extraction 24 Connection for extraction 24 External fans 25 Tech...

Страница 3: ...recycling Disposal of your old appliance Old machines appliances contain ma terials which can be reclaimed or re cycled Please contact your dealer your waste collection centre or scrap merchant about potential recycling schemes Ensure that the machine appliance presents no danger to children while being stored for disposal Before discarding an old ap pliance render it useless Discon nect the cable...

Страница 4: ...Guide to the appliance Guide to the appliance 4 ...

Страница 5: ...pending on how much the air needs to be filtered l Touch control for the run on option This control activates the run on option The fan is switched off automatically after either 5 or 15 minutes m Touch control for the grease filter The indicator lamp on the grease filter touch control lights up when the grease filter needs to be cleaned The touch control is used to count down the time which is sh...

Страница 6: ...itched off No exchange of room air and outside air can take place When the cooker hood is switched on the non return flap opens for the cooking smells to be blown di rectly outside an External Fan The EX models of cooker hoods are de signed to be connected with an external fan The external fan is connected to the cooker hood by means of a control cable and is operated by the control panel on the c...

Страница 7: ... The electrical safety of this ap pliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national regulations It is most import ant that this basic safety requirement is tested by a qualified electrician The manufacturer cannot be held re sponsible for the consequences of an inadequate earthing system e g elec...

Страница 8: ...e and hindering its smooth oper ation Clean or change the filter regularly An over greasy filter is a fire ha zard Under no circumstances use a steam cleaner to clean this ap pliance Pressurised steam could reach the electrical components and cause a short circuit Installation The distance between the top of the cooker hob and the bottom of the cooker hood must measure at least 55 cm above electri...

Страница 9: ...of the dwelling must be taken into ac count If in any doubt the advice of a compe tent builder or for gas a Corgi instal ler must be sought In countries which may be subject to infestation by cockroaches or other vermin pay particular attention to keeping the appliance and its surround ings in a clean condition at all times Any damage which might be caused by cockroaches or other vermin will not b...

Страница 10: ...h a strong aroma the highest level is recom mended Depending on model the top setting is marked IS Intensive Setting Use the touch control to select the power level required Touch control higher setting Touch control lower setting The indicator lamps show which power level has been chosen Run on option If the air still needs to be cleared after cooking the cooker hood can be set to continue runnin...

Страница 11: ...o switch the fan off Switching the lighting on or off The lighting for illuminating the hob can be switched on or off independently of the fan Press the lighting touch control When it is switched on the lighting indi cator lamp glows Operation 11 ...

Страница 12: ...he grease filter touch control and hold for about 4 seconds The indicator lamp will go out Reading the filter operating time counter Before reaching the end of the period set you can check the percentage of the time set which has already passed Use the On Off touch control to switch the fan on Press the grease filter touch control One or several of the indicator lamps for the touch control will fl...

Страница 13: ...cator lamp for the grease filter touch control and one of the control lamps for the touch control will flash The touch control lamps show the time which has been set 1st lamp from left 20 hours 2nd lamp from left 30 hours 3rd lamp from left 40 hours 4th lamp from left 50 hours Use the touch control to select the desired time Confirm the procedure by pressing the grease filter touch control If the ...

Страница 14: ...se a cleaner which scours or contains chlorine acids or soda These would damage the surface of the cooker hood For stainless steel surfaces a mild non abrasive proprietary stainless steel cleaner is suitable Grease filter A re usable metal grease filter is fitted which removes solid particles oil dust etc from the kitchen vapours prevent ing soiling of the cooker hood The grease filter should be c...

Страница 15: ...ffect the functioning of the grease filter in any way After cleaning leave the filter to dry for a while on an absorbent surface before putting it back in place When removing the filter for cleaning also clean off any residues of oil or fat from the housing to prevent the risk of these catching fire To replace the filter insert the left hand side first and then push the right hand side upwards unt...

Страница 16: ... mediately as they remain hot for some time after being switched off Do not touch the bulb surface di rectly when changing the bulb as this will damage it fat particles ad here to the surface Please follow the manufacturer s instructions To change the halogen bulb first remove the outer ring b Then detach the circlip c taking care that the glass cover d does not fall out The halogen bulb e is fitt...

Страница 17: ...tact Your dealer or Your nearest Service Dept see ad dress on back page When contacting the Service depart ment please quote the Model and Ser ial number of your appliance both of which are given on the data plate which is visible on removing the grease filter After sales service 17 ...

Страница 18: ...be connected to the termi nal in the plug which is marked with the letter E or by the earth symbol z or col oured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red WARNING THIS APPLIANCE MU...

Страница 19: ... of the cooker hob and the bottom of the cooker hood should be at least 55 cm above electric cookers hobs 65 cm above gas cookers hobs A distance of 65 cm may be preferable to give more working space Mark a line on the ceiling centrally above the hob Make a hole in the ceiling for the ex haust hose at the required position Installation 19 ...

Страница 20: ...he ceiling space If the cooker hood is to be con nected to an external fan motor cre ate a gap for the connection cable to the fan motor Ensure that the diameter is sufficient to be able to feed through a 6 pole connector Drill four 10 mm ø holes in the ceiling and insert S10 plugs into the holes Prepare the ceiling plate for fitting Push up the spring clips e through the slots from below Insert t...

Страница 21: ...it necessary Make the connection between the cooker hood and the external fan with the 6 pole connector Assemble the tower Place the flange plate of the tower onto the ceiling plate in such a way that the spring clips click into the slots securely Screw the flange plate firmly to the ceiling plate with the M6 nuts the toothed lock washers and the flat washers When doing this ensure that the toothe...

Страница 22: ...ible and secure inside the cooker hood chim ney with the cable clips Ensure all safety regulations are complied with Finally push the cover frame up wards until the spring fixing clips click in securely and the frame lies tightly against the ceiling Installation 22 ...

Страница 23: ...lamped in place by a ball mech anism To do this tighten the 4 inner hexago nal screws on each side Dismantling the glass panels To dismantle a glass panel hold the glass panel firmly and loosen the 4 inner hexagonal screws Pull the panel out of the housing to wards the side Although the edges of the glass pa nels are smoothed it is advisable to wear protective gloves when hand ling them Installati...

Страница 24: ...oise level of the cooker hood Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth or flexible pipes made from non flammable materials for extraction connection When ducting is horizontal it must be laid to slope away at 1 cm per metre to ensure no condensate drains into the appliance If the exhaust air is to be ducted into the open air the installati...

Страница 25: ...h mm depth mm height mm Ø 301 244 380 460 230 380 460 160 Ø 301 124 360 400 245 310 280 390 390 Installed on flat roof on pitched roof on in outside wall free choice X X X X X X Air through put unducted in practice pipe con nection 850 m3 h 730 m3 h Ø 150 mm 950 m3 h 780 m3 h Ø 150 mm 125 mm 950 m3 h 780 m3 h Ø 150 mm 125 mm 850 m3 h 730 m3 h Ø 150 mm 900 m3 h 720 m3 h Ø 150 mm 125 mm 850 m3 h 730...

Страница 26: ...tructions for the wall fan Remove the four fixing screws and take off the housing lid Mark where the holes for the screws are to be drilled Then drill the holes and insert plugs Screw the housing together Position the interior telescopic part and insert foam into the intervening space Secure the stainless steel lid to the housing Fit the extraction flexible hose and connect the control cable conne...

Страница 27: ...ata Rated load 340 W Motor 2 x 130W Lighting 4 x 20 W Voltage 220 230 V Frequency 50 Hz Fusing 13 A G B Fan power Extraction according to DIN 44971 Level 1 3 290 500 m3 h Level IS 720 m3 h unrestricted 785 m3 h Technical data 27 ...

Страница 28: ...M No 08 251 800 02 1098 Alteration rights reserved ...