*INSTALLATION*

Installing the SmartLine element

Stick the supplied sealing strip under
the edge of the SmartLine element.
Do not apply the sealing strip under
tension.

Feed the mains connection cable
down through the worktop cutout.

Position the SmartLine element in the
worktop cutout. When doing this,
make sure that the seal of the
appliance sits flush with the worktop
on all sides. This is important to
ensure an effective seal all round.

If the seal does not meet the worktop
correctly on the corners, carefully
scribe the corner radii (

 R4) with a

jigsaw.

Do not use any additional sealant
(e.g. silicone) on the SmartLine
element.

Connect the SmartLine element to
the mains electricity supply.

If required, connect the SmartLine
element to the gas supply (see
“Installation – Gas connection”).

Check that the SmartLine element
works.

Seal the gaps between the individual
elements with a silicone sealant that
is heat-resistant to at least 160 °C.

Unsuitable sealant can damage
natural stone.
For natural stone worktops and
natural stone tiles, only use silicone
sealant that is specially formulated
for natural stone. Follow the
manufacturer’s instructions.

Содержание hdsn-30 CS 7641 FL

Страница 1: ...s and the cooker hood before the SmartLine element The veneer or laminate coatings of worktops or adjacent kitchen units must be treated with 100 C heat resistant adhesive which will not dissolve or distort Any backmoulds must be of heat resistant material The SmartLine element must not be installed over a fridge fridge freezer freezer dishwasher washing machine washer dryer or tumble dryer This S...

Страница 2: ...ed between the SmartLine element and the cooker hood above it If combustible objects are installed above the SmartLine element e g cabinets utensil rail etc a minimum safety distance of 600 mm must be maintained When two or more SmartLine elements which have different safety distances are installed together below a cooker hood you should observe the greatest specified safety distance ...

Страница 3: ...ide of the SmartLine element right or left and a tall unit or room wall A minimum distance of 300 mm must be observed on the opposite side Minimum distance between the back of the worktop cut out and the rear edge of the worktop 50 mm Minimum distance on the right side between the worktop cut out and the closest adjacent piece of furniture e g tall unit or a room wall 50 mm Minimum distance on the...

Страница 4: ...nce from the lower edge of the SmartLine element to Upper edge of oven 15 mm Upper edge of interim shelf 15 mm Upper edge of drawer 5 mm Base of drawer 75 mm Intermediate shelf It is not necessary to fit an interim shelf underneath the SmartLine element but one may be fitted if you wish Leave a gap of 10 mm at the back of the shelf to accommodate the mains connection cable We recommend a gap at th...

Страница 5: ... must be maintained between the worktop cut out and the cladding If the niche cladding is made from a non combustible material e g metal natural stone ceramic tiles the minimum safety distance between the worktop cut out and the cladding will be 50 mm less the thickness of the cladding Example 15 mm niche cladding 50 mm 15 mm minimum safety distance of 35 mm Flush fit installation Onset installati...

Страница 6: ...appliance provides a sufficient seal for the worktop Tiled worktop Grout lines and the hatched area underneath the SmartLine element frame must be smooth and even If they are not the SmartLine element will not sit flush with the worktop and the sealing strip underneath the top part of the appliance will not provide a good seal between the appliance and the worktop Sealing strip Dismantling the Sma...

Страница 7: ...t 160 C After installation the SmartLine elements must be easily accessible from below so that the bottom half of the casing can be removed for maintenance If the SmartLine elements are not accessible from below the sealant must be removed so that they can be removed Combination with a downdraft extractor If the SmartLine element is installed in combination with a downdraft extractor the latter mu...

Страница 8: ... several elements a distance of 2 mm must be observed between the individual elements Calculating cutout dimension B 1 element Width of the element minus 10 mm on the right minus 10 mm on the left Several elements Total width of the elements plus 2 mm distance between the elements minus 10 mm on the right minus 10 mm on the left Some examples are illustrated below ...

Страница 9: ...tractor Combination examples Number x width mm Dimension B mm Cooking elements Downdraft extractor 1 x 378 1 x 120 480 1 2 x 378 1 x 120 860 1 1 x 378 1 x 620 2 x 120 1224 1 3 x 378 2 x 120 1362 1 2 x 378 1 x 620 2 x 120 1604 1 4 x 378 2 x 120 1742 1 1 x 620 2 x 120 844 1 ...

Страница 10: ...NSTALLATION Installation without a downdraft extractor Combination examples Number x width mm Dimension B mm Cooking elements 1 x 378 358 1 2 x 378 738 1 1 x 378 1 x 620 980 1 3 x 378 1118 1 2 x 378 1 x 620 1360 1 4 x 378 1498 1 ...

Страница 11: ...ce mounted When installing several SmartLine elements an additional spacer bar must be fitted in between the individual elements The clips supplied with the spacer bars are only required for installing a CSDA 700x FL Installing 3 elements and 2 spacer bars ...

Страница 12: ...11782200 00 Installation INSTALLATION Installation dimensions Surface mounted All dimensions are given in mm a Front b Power cable L 2000 mm ...

Страница 13: ...nto contact with the top of the worktop Fitting the spacer bars Use the middle screw holes if one of the following SmartLine elements is installed to the right or left of the spacer bar CS 7611 CS 7641 CS 7101 1 CS 7102 1 Wooden worktops Position the spacer bars flush onto the upper edge of the cutout Secure the spacer bars with the 3 5 x 25 mm wood screws supplied Natural stone worktops You will ...

Страница 14: ...not meet the worktop correctly on the corners carefully scribe the corner radii R4 with a jigsaw Do not use any additional sealant e g silicone on the SmartLine element Connect the SmartLine element to the mains electricity supply If required connect the SmartLine element to the gas supply see Installation Gas connection Check that the SmartLine element works Seal the gaps between the individual e...

Страница 15: ... is easily accessible from underneath after installation and the bottom half of the casing can be removed for maintenance If the element is not freely accessible from below after installation the sealant must be removed so that the element can be removed Natural stone worktops The SmartLine element is set directly in the cutout Solid wood worktops tiled worktops glass worktops The SmartLine elemen...

Страница 16: ...t 160 C After installation the SmartLine elements must be easily accessible from below so that the bottom half of the casing can be removed for maintenance If the SmartLine elements are not accessible from below the sealant must be removed so that they can be removed Combination with a downdraft extractor If the SmartLine element is installed in combination with a downdraft extractor the latter mu...

Страница 17: ... a distance of 2 mm must be observed between the individual elements Calculating cutout dimension A 1 element Width of the element plus 2 mm on the right plus 2 mm on the left Several elements Total width of the elements plus 2 mm distance between the elements plus 2 mm on the right plus 2 mm on the left Calculating cutout dimension B Cutout dimension A minus 12 mm on the right minus 12 mm on the ...

Страница 18: ...ber x width mm Dimensi on A mm Dimensi on B mm Cooking elements Downdraft extractor 1 x 378 1 x 120 504 1 480 1 2 x 378 1 x 120 884 1 860 1 1 x 378 1 x 620 2 x 120 1248 1 1224 1 3 x 378 2 x 120 1386 1 1362 1 2 x 378 1 x 620 2 x 120 1628 1 1604 1 4 x 378 2 x 120 1766 1 1742 1 1 x 620 2 x 120 868 1 844 1 ...

Страница 19: ...hout a downdraft extractor Combination examples Number x width mm Dimension A mm Dimension B mm Cooking elements 1 x 378 382 1 358 1 2 x 378 762 1 738 1 1 x 378 1 x 620 1004 1 980 1 3 x 378 1142 1 1118 1 2 x 378 1 x 620 1384 1 1360 1 4 x 378 1522 1 1498 1 ...

Страница 20: ...ush fit When installing several SmartLine elements an additional spacer bar must be fitted in between the individual elements The clips supplied with the spacer bars are only required for installing a CSDA 700x FL Installing 3 elements and 2 spacer bars ...

Страница 21: ...ns Flush All dimensions are given in mm a Front b Power cable L 2000 mm c Stepped cutout for detailed illustrations see Installation Worktop cutout flush fit d 12 mm wooden frame not supplied for detailed illustrations see Installation Worktop cutout flush fit ...

Страница 22: ...e upper edge of the worktop For CS 7611 FL the wooden frame must be secured 7 mm under the upper edge of the worktop Fitting the spacer bars Use the middle screw holes if one of the following SmartLine elements is installed to the right or left of the spacer bar CS 7611 CS 7641 CS 7101 1 CS 7102 1 Wooden worktops Position the spacer bars flush onto the lower step of the stepped cutout Secure the s...

Страница 23: ...his is important to ensure an effective seal all round Connect the SmartLine element to the mains electricity supply If required connect the SmartLine element to the gas supply see Installation Gas connection Check that the SmartLine element works Seal the gaps between the individual elements and between the elements and the worktop with a silicone sealant that is heat resistant to at least 160 C ...

Страница 24: ...of the local electricity provider e g BS 7671 in the UK After installation ensure that all electrical components are shielded and cannot be accessed by users Total power rating See data plate Connection data The connection data is quoted on the data plate Please ensure these match the household mains supply Residual current device For extra safety it is advisable to protect the SmartLine element w...

Страница 25: ...etely remove fuses Automatic circuit breakers Press the red test button until the middle black button springs out Built in circuit breakers Circuit breakers at least type B or C Switch the lever from 1 on to 0 off Residual current device RCD Switch the main switch from 1 on to 0 off or press the test button Connecting the mains cable Danger of electrical shock The mains connection cable must only ...

Отзывы: