Warning and Safety instructions
6
Technical safety
The coolant circuit has been checked for leaks. The refrigeration
appliance complies with statutory safety requirements and the ap-
propriate EU directives.
This refrigeration appliance contains the refrigerant isobutane
(R600a), a natural gas which is environmentally friendly but flam-
mable. The refrigerant does not damage the ozone layer and does
not contribute to the greenhouse effect.
The use of this refrigerant has, however, led to a slight increase in
the noise level of the appliance. In addition to the noise of the com-
pressor, you might be able to hear the refrigerant flowing around the
cooling circuit. Unfortunately, this cannot be avoided, but it does not
affect the performance of the refrigeration appliance.
When transporting and installing the refrigeration appliance, ensure
that no parts of the cooling circuit are damaged. Splashes of refri-
gerant can damage the eyes.
In the event of damage:
- Avoid naked flames or anything which creates a spark.
- Disconnect the refrigeration appliance from the mains electricity
supply.
- Ventilate the room where the refrigeration appliance is located for
several minutes.
- Contact the Miele Customer Service Department.
The more coolant there is in a refrigeration appliance, the larger
the room it should be installed in. In the event of a leakage, if the ap-
pliance is in a small room, there is the danger of a combustible gas/
air mixture building up. For every 11 g of coolant at least 1 m
3
of
room space is required. The amount of coolant in the refrigeration
appliance is stated on the data plate inside the appliance.
Содержание F 31202 Ui
Страница 17: ...Guide to the appliance 17 a Control panel with display b Freezer drawers c Ventilation grille ...
Страница 65: ......
Страница 66: ......
Страница 68: ...M Nr 10 838 160 02 en GB F 31202 Ui ...