Description of functions
35
Control panel
The water container is located behind
the control panel. The panel is opened
and closed by touching the
Lift
Panel
sensor button. Before the control
panel closes automatically, a note ap-
pears in the display, which you must
confirm with
OK
.
The control panel is fitted with anti-trap-
ping protection. If the control panel
senses resistance when opening/clos-
ing, the process is canceled. Do not
touch the upper edge of the door when
the panel is opening and closing.
Water container
Water is pumped into the water con-
tainer and then into the steam genera-
tor.
A fault can occur if the opening to
the water container is blocked.
The opening on the front of the water
container must not be blocked as
otherwise water cannot be pumped
into the steam generator.
Food probe
The probe measures the core tempera-
ture in the food, enabling the tempera-
ture during the cooking process to be
monitored simply and accurately.
Temperature/core temperature
Some functions have a preset recom-
mended temperature. The recom-
mended temperature can be altered
within the given range for an individual
cooking program, a program stage, or
for every time that program is used (see
“Recommended temperatures” under
“Settings”).
The core temperature can also be al-
tered within the given range for an indi-
vidual program or a specific program
stage.
Moisture
The
Combi Steam
operating mode
and
Reheat
Special Mode use a combi-
nation of oven heat and moisture. The
moisture level can be selected within
the given range for an individual pro-
gram or a specific program stage.
Depending on the moisture setting,
moisture or fresh air is supplied to the
oven compartment. With the moisture
setting = 0%, the maximum fresh air
supply is implemented and no moisture
is supplied. With the moisture set-
ting = 100%, there is no fresh air supply
and the moisture content is at its maxi-
mum.
Some food gives off moisture during
the cooking process. This moisture
from the food affects the amount of ad-
ditional moisture needed. If the required
amount of moisture is low, the steam
generator may not be activated at all.
Содержание DGC 7785
Страница 23: ...Overview 23 a Water container b Data plate c Compartment for water container ...
Страница 179: ...Installation INSTALLATION 179 Side view A DGC 78xx 1 7 8 47 mm ...
Страница 183: ...Installation INSTALLATION 183 Side view A DGC 77xx 2 1 2 64 mm DGC 78xx 1 7 8 47 mm ...
Страница 193: ...Declaration of conformity 193 Frequency band 2 412 GHz 2 462 GHz Maximum trans mitting power 100 mW ...
Страница 196: ...M Nr 11 924 030 00 en US CA DGC 7865 DGC 7785 DGC 7885 ...