The filters should be regularly
cleaned, or changed, as appropri-
ate.
Saturated filters are a fire hazard.
Under no circumstances use a
steam cleaner to clean this ap-
pliance.
Pressurised steam could give rise to a
short circuit or cause permanent dam-
age to the surface and components, for
which the manufacturer of the cooker
hood cannot accept any responsibility.
Installation
The distance between the top of
the hob and the bottom of the
cooker hood must measure at least:
– 55 cm above electric hobs
– 65 cm above gas hobs
The distance of 65 cm between
the cooker hood and a gas hob is
a minimum, which is only permissible if
the nominal heat ratings given in the
table below are not exceeded:
Gas cooker
maximum
nominal rating
one burner
2.7 kW
all burners
7.5 kW
oven
3.5 kW
Gas hob
maximum
nominal rating
one burner
3.5 kW
all burners
10.3 kW
Gas hob with ceramic cover plate
The data given for the maximum nominal (heat)
ratings do not apply to a gas hob with a ceramic
cover plate. In this case it is essential to refer to
the hob manufacturer’s data.
Safety regulations prohibit the fit-
ting of a cooker hood over solid
fuel stoves.
All ducting, pipework and fittings
must be of non-flammable mate-
rial. These can be obtained from the
Miele Spare Parts department or from
builders’ merchants.
The appliance must not be con-
nected to a chimney or vent flue
which is in use. Neither should it be
connected to ducting which ventilates
rooms with fireplaces.
If exhaust air is to be extracted into
a chimney or ventilation duct no
longer used for other purposes, take
professional advice.