Installation
47
a
Extraction ducting upwards or to the rear.
b
Cut-out for cooker hoods with hard-wired connection rather than a plug.
c
200 mm
cut-out ensures sufficient space through the wall for the extraction
ducting to flex.
d
Ventilation outlet for recirculation mode. A gap of at least 300 mm must be
maintained between the top of the cooker hood and the ceiling or any furniture
above it.
Connection for air extraction
150 mm, or
125 mm with reducing collar.
Please observe installation positions for the socket and for the ducting outlet
shown on the relevant drawings when using the DADC 6000 tower.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See „Warning and Safety“ instructions for further information.
Cooking appliance
Minimum distance S
Electric hob
450 mm
Electric grill, deep fat fryer (electric)
650 mm
Multi-burner gas hob,
total output
≤
12.6 kW, no burner
>
4.5 kW
650 mm
Multi-burner gas hob,
total output
>
12.6 kW and
≤
21.6 kW,
no burner
>
4.8 kW.
760 mm
Multi-burner gas hob,
total output
>
21.6 kW,
or multi-burner gas hob where one burner
>
4.8 kW.
Not possible
Single burner gas hob, output
≤
6 kW.
650 mm
Single burner gas hob, output
>
6 kW and
≤
8.1 kW.
760 mm
Single burner gas hob, output
>
8.1 kW
Not possible