manualshive.com logo in svg
background image

Operating and Installation
Instructions

Ventilation System
DA 6290 W

To prevent accidents
and appliance damage,
read these instructions

before

installation or use.

M.-Nr. 07 851 420

en - US, CA

Содержание DA 6290 W

Страница 1: ...Operating and Installation Instructions Ventilation System DA 6290 W To prevent accidents and appliance damage read these instructions before installation or use M Nr 07 851 420 en US CA ...

Страница 2: ...4 Cleaning and Care 16 Cleaning the casing 16 Grease filter 17 Resetting the grease filter timer 18 Active charcoal filter 19 Resetting the charcoal filter timer 19 Changing the light bulbs 20 After Sales Service 21 Installation instructions 23 Caring for the environment 25 Appliance dimensions 26 Plywood backing 30 Installation 31 Installation instructions 31 Protective film 31 Dismantling 31 Ins...

Страница 3: ...sed in a non stationary location e g on a ship WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this appliance only in the manner intended by the manufacturer If you have questions contact Miele b Before servicing or cleaning the appliance switch power off at the service panel and lock the service disconnecting means to prevent power from being swi...

Страница 4: ...lectrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults g Before discarding an old appliance disconnect it from the power supply and remove the power cord to prevent hazards Use WARNING TO REDUCE THE RISK OF A COOKTOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers may ...

Страница 5: ...fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NAFTA Do not allow children to play with or operate the appliance or its controls Supervise its use by the elderly or infirm Always turn on the hood when using the cooktop to prevent damage from condensation Never operate gas burners without cookware Turn the burner off ...

Страница 6: ...control device f Do not use an extension cord to connect the appliance to electricity Extension cords do not guarantee the required safety of the appliance e g danger of overheating g Do not install this hood over cooktops that burn solid fuel h Provided a larger distance is not given by the manufacturer of the cooktop follow the minimum safety distances between a cooktop and the bottom of the hoo...

Страница 7: ...re of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside Recirculation mode Air is drawn through the grease filters and an active charcoal filter The filtered air is then recirculated back into the kitchen through a vent at the top of the hood s chimney The recirculation mode requires an install kit and charcoal filter which are optional accessories Befor...

Страница 8: ...Guide to the Ventilation System 8 ...

Страница 9: ...can be set to turn off automatically after either 5 or 15 minutes oFilter button The indicator l of the grease filter button lights when the grease filters need to be cleaned The indicator next to the charcoal filter button lights when the charcoal filter needs to be replaced When first using the system the operating hours timer must be activated This button can be used at any time to reset the ap...

Страница 10: ... usually sufficient for normal cooking Intensive setting Level 4 should be used for a short period when frying or cooking food with a strong aroma Automatically switching back the intensive power level The intensive level 4 can be programmed to automatically switch back to level 3 after 10 minutes Turn the fan and the lights off Press and hold the Delay Shut down button for 10 secs The first indic...

Страница 11: ...ave the setting press the Delay Shut Down button If the procedure is not stored within 4 minutes of programming the hood will automatically default to the old data Fan performance The maximum air flow capacity is 625 cfm Factors such as narrow duct diameter and bends will affect this value Level 1 operates at 40 capacity Level 2 operates at 60 capacity Level 3 operates at 80 capacity Level 4 opera...

Страница 12: ...rning off the fan K Press the On Off button to turn the fan off K The K indicator goes out Overhead lighting I The overhead lighting can be turned on and off independently of the fan Press the light button I briefly to turn on the lighting The I light button indicator illuminates The overhead lighting comes on at maximum brightness Dimming the overhead lighting The brightness of the lighting can b...

Страница 13: ...but the colors rotate once every 15 minutes Initially the button indicator flashes slowly A selected light color can be saved To select the color Select the rapid or slow color sequence color setting e or f The continuous color changes start When the desired color is reached press and hold the color change button until the glass edge lighting flashes three times This light color is now saved as an...

Страница 14: ... will harden over time making cleaning difficult The factory setting for the grease filter timer is 30 hours You can adjust the time to 20 30 40 or 50 hours Press the On Off button K to turn off the fan Press the Delayed Shut Down 5 15 and filter button l at the same time The indicator for the grease filter timer l and one of the power level indicators will flash The 1 to IS indicators show the pr...

Страница 15: ...m the selection by pressing the filter timer button l All the indicator lights will go out If the procedure is not stored within 4 minutes the hood will automatically default to the original setting Reading the filter operating hours counter To check the percentage of time set already used Press the On Off control s to switch the fan on Press and hold the filter button l Once to read the Grease fi...

Страница 16: ...damage Wipe dry using a soft cloth Avoid cleaning agents containing soda acids or chlorides abrasive cleaning agents e g powder or cream cleansers abrasive sponges e g pot scourers or sponges which have been previously used with abrasive cleaning agents These will damage the surface The following instructions for cleaning Stainless steel surfaces and Stainless steel colored controls should be foll...

Страница 17: ...usable metal grease filters in the hood remove solid particles from the vented kitchen air grease dust etc and prevent soiling of the ventilation system The grease filters should be cleaned every 3 4 weeks or when the grease filter indicator lights A dirty filter is a fire hazard To remove the grease filter pull the locking clips forward lower the filter down 45 unhook it at the rear and take it o...

Страница 18: ...lter surface Filter performance will not be affected by this discoloration After cleaning place the filters on a towel to air dry While the filters are removed clean any dirt or grease from the filter casing When putting the grease filters back make sure that the locking clips are visibly facing the cooking surface If the filters are incorrectly installed insert a small screwdriver into the slit a...

Страница 19: ...ilter Before using Program the charcoal filter timer see Operation Activating and reprogramming the charcoal filter timer Replace the active charcoal filter when the charcoal filter indicator lights at least every 6 months or when they no longer absorb odors efficiently Used charcoal filters may be discarded in household trash Resetting the charcoal filter timer After replacing reset the charcoal ...

Страница 20: ...xtremely hot and can burn your hands Do not attempt to change the bulbs until they have had sufficient time to cool To change the halogen bulb first gently press the light cover The cover will open and can now be flipped down Pull the halogen bulb from its socket Using a cloth or glove insert the new halogen bulb type 12 V 20 W G4 Please follow the manufacturer s instructions Flip the light cover ...

Страница 21: ...ustry that guarantees repairs by a Miele Authorized Service Provider using genuine Miele parts Only genuine Miele parts installed by factory trained professionals can guarantee the safety reliability and longevity of your Miele appliance Please note that unless expressly approved in writing by Miele s Service department Extended Service Contracts offered by other providers for Miele products will ...

Страница 22: ...22 ...

Страница 23: ...g this ventilation system The installation steps are described in the enclosed Installation Diagram Leave these instructions with the appliance for the consumer user Information is subject to change Please refer to our website to obtain the most current product specification technical warranty information ...

Страница 24: ...24 ...

Страница 25: ...sed of safely and kept out of the reach of babies and young children Danger of suffocation Disposal of an old appliance Old appliances may contain materials that can be recycled Please contact your local recycling center about the possibility of recycling these materials Before discarding an old appliance disconnect it from the electrical supply and cut off the power cord to prevent it from becomi...

Страница 26: ...Drawing is not to scale Appliance dimensions 26 ...

Страница 27: ...tion mode only d e Installation area For recirculation mode only d Wall ceiling area respectively for vent hole and outlet installation For recirculation mode only the outlet installation is required Connection for air extraction mode 6 150 mm with reducing collar 5 125 mm Appliance dimensions 27 ...

Страница 28: ...he gas cooktop manufacturer to easily flammable materials e g upper cabinets If local building codes require a greater safety distance follow their requirement If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance See Important Safety Instructions for further information To ensure free access to work under the venti...

Страница 29: ...plate the spacings for the 5 mm screws need to be drilled as shown If the ventilation hood will be mounted directly to the wall follow the additional instructions given in the included Installation diagram Appliance dimensions 29 dai2542us ...

Страница 30: ...nstall a plywood backing Determine and mark the location of the retaining plate for the canopy as outlined on the Installation diagram Make a cutting line 3 76 mm above and 3 76 mm below the outline of the retaining plate Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line along the center of each stud CAUTION When c...

Страница 31: ...film stainless steel units The casing is covered with a protective film to prevent scratching during transport Please peel off the film before installing the casing parts It can be removed without tools Dismantling If the hood needs to be disassembled follow the instructions on the Installation diagram in the reverse order A lever is enclosed for easier removal of the chimney extension After remov...

Страница 32: ...Installation materials Installation 32 ...

Страница 33: ...lation mode contains diverter hose and hose clips optional accessory 6 Screws 5 x 40 mm S8 wall anchors included in the packaging are not for use in USA CDN The screws and wall anchors are suitable for solid brick walls For other wall constructions use appropriate materials Ensure that the wall can support the weight 2 M 6 locking nuts for securing the motor assembly 2 Screws 3 9 x 7 5 mm for secu...

Страница 34: ... Use smooth or flexible pipework made from approved non flammable materials for exhaust ducting To achieve the most efficient air extraction and quietest noise levels consider the following The diameter of the ductwork should not be less than 6 150 mm If flat ducting is used the cross section must not be smaller than the cross section of the ventilation exhaust The ducting should be as short and s...

Страница 35: ...Important If the ductwork runs through rooms ceilings garages etc where temperature variations exist it may need to be insulated to reduce condensation Condensate trap optional accessory In some cases a condensate trap may also be required to collect and evaporate any condensate which may occur This optional accessory is available for ducts 5 125 mm and 6 150 mm in diameter When installing a conde...

Страница 36: ...his appliance to your power supply please consult a licensed electrician or contact Miele s Technical Service Department U 1 800 999 1360 V 1 800 565 6435 WARNING THIS APPLIANCE MUST BE GROUNDED Grounding Instructions This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing a path of least resistance This appliance is equ...

Страница 37: ...d load 420 W fan motor 350 W direct lighting 3 x 20 W lighting on glass edges 10 W Power supply voltage 120 V Frequency 60 Hz Circuit rating 15 A Length of power cord 4 11 1 5 m Weight 62 lbs 28 kg Technical data 37 ...

Страница 38: ...38 ...

Страница 39: ...39 ...

Страница 40: ...Alteration rights reserved 1711 INFORMATION IS SUBJECT TO CHANGE PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS TECHNICAL WARRANTY INFORMATION M Nr 07 851 420 01 ...

Отзывы: