Connection for air extraction
50
Before installation, it is important
to read the information given on the
following pages as well as the
"Appliance dimensions" and the
"Warning and Safety instructions" at
the beginning of this booklet. This is
particularly crucial when using the
rangehood at the same time as a
heating appliance that relies on
oxygen from the same room, which
could result in the build-up of toxic
fumes.
The rangehood should be installed
according to local and national
building regulations. Seek approval
from the building inspector where
necessary.
Only use smooth pipes or flexible
hoses made from non-flammable
materials for the extraction ducting.
Highly flexible, concertina type
ducting material will greatly reduce
the performance of the rangehood.
When using an external motor, make
sure that the exhaust ducting is
sufficiently rigid. The external motor
can cause an underpressure which
can result in the exhaust ducting
distorting.
To achieve the greatest possible air
extraction with the lowest noise level,
please note the following:
To ensure efficient air extraction, the
diameter of the exhaust ducting
should not be less than 150 mm.
– A reduction in diameter will
compromise the extraction
performance of the rangehood.
– If flat ducting is being used, the
cross-sectional area must not be
smaller than the cross-sectional area
of the exhaust connection.
– The exhaust ducting should be as
short and straight as possible.
– Only use wide radius bends.
– The exhaust ducting should not be
kinked or compressed.
– Ensure that all connections are
strong and airtight.
Remember that any constriction of
the airflow will reduce extraction
performance and increase operating
noise.
If the exhaust is ducted through an
outside wall, a telescopic wall vent or
a roof vent (available as an optional
accessory) is recommended.
If the exhaust air is to be ducted into
a vent flue, the ducting must be
directed in the flow direction of the
flue.
Содержание DA 420V-6
Страница 2: ......
Страница 30: ......
Страница 68: ...Loading the dishwasher 40 Loading examples Dishwashers with cutlery tray Upper basket Lower basket ...
Страница 69: ...Loading the dishwasher 41 Cutlery tray Heavily soiled items ...
Страница 70: ...Loading the dishwasher 42 Dishwashers with cutlery basket Upper basket Lower basket ...
Страница 71: ...Loading the dishwasher 43 Cutlery basket Heavily soiled items ...
Страница 73: ...Comparison tests 45 Capacity 14 Upper basket Lower basket ...
Страница 74: ...Comparison tests 46 Cutlery basket 1 fork 2 soup spoons ...
Страница 76: ...Comparison tests 48 Capacity 14 ...
Страница 77: ...Comparison tests 49 ...
Страница 128: ...M Nr 11 693 870 01 en AU NZ G 5210 ...
Страница 194: ......
Страница 196: ...M Nr 11 274 100 04 en AU NZ SG KM 7200 FR KM 7201 FR KM 7210 FR KM 7262 FR ...
Страница 214: ...Installation 18 Side view 455 5 451 5 333 111 5 22 22 23 3 4 min 2 Glass Stainless steel ...
Страница 220: ...Guide to the appliance 24 a Control panel b Grill c Turntable d Door e Grilling rack f Gourmet plate ...
Страница 284: ...M Nr 11 195 170 00 en AU NZ M 7244 TC ...
Страница 300: ...Oven controls 16 a Function selector b Clock Timer c Temperature selector ...
Страница 375: ...Building in diagrams 91 Installation in a tall unit Ovens with glass front Ovens with metal front ...
Страница 378: ......
Страница 380: ...M Nr 10 011 630 03 en AU NZ H6290B ...
Страница 396: ...Guide to the appliance 16 ...
Страница 429: ...Installation 49 Carefully remove the protective foil from the grease filters Refit the grease filters ...
Страница 436: ......
Страница 437: ......
Страница 438: ......
Страница 440: ...M Nr 09 823 990 03 en AU DA 420V 6 DA 420V 6 EXT DA 424V 6 DA 424V 6 EXT ...