Important:
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the
problem of condensation will need to
be addressed. The exhaust ducting will
need to be suitably insulated.
Condensate trap
(optional extra)
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is also installed to
collect and evaporate any condensate
which may occur. Condensate traps are
available for
C
125 mm or
C
150 mm
ducting.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust connection. The arrow on the
housing indicates the direction of
air-flow.
Connection for air extraction
23
Содержание DA 396
Страница 10: ...Guide to the appliance 10 ...
Страница 18: ...Assembly parts Installation 18 ...
Страница 26: ...26 ...
Страница 27: ...27 ...
Страница 28: ...Alteration rights reserved 0805 M Nr 06 417 570 03 en GB ...