Страница 1: ...Operating and Installation Instructions Ventilation System DA 362 75 DA 362 110 To prevent accidents and machine damage read these instructions before installation or use UV M Nr 06 191 500 ...

Страница 2: ...s 13 Checking the filter timers 13 Reprogramming the timers 14 Cleaning and care Cleaning the casing 16 Grease filters 17 Active charcoal filters 19 Changing the light bulb 20 After Sales Service Installation instructions Caring for the environment Electrical data Appliance dimensions Installation Air extraction mode 30 Recirculation mode 31 Installing the joystick 33 Joystick extension 33 Electri...

Страница 3: ...ctrical safety of this appliance continuity must exist between the appliance and an effective grounding system It is imperative that this basic safety requirement be met If there is any doubt have the electrical system of the house checked by a qualified electrician The manufacturer can not be held responsible for damages caused by the lack or inadequacy of an effective grounding system Before con...

Страница 4: ...ce unplug it from the power supply and remove the power cord and any doors to prevent hazards Use Do not allow children to play with or operate the appliance or its controls Supervise its use by the elderly or infirm Be careful when preparing a flambé beneath the hood Flames may be drawn up into the hood by the suction or grease filters may catch fire Never operate gas burners without pots Do not ...

Страница 5: ...OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explo...

Страница 6: ...ion cords do not guarantee the required safety of the appliance e g danger of overheating Do not install this hood over cooktops burning solid fuel Any fittings sealant or materials used to install the ductwork must be made of approved non flammable materials Never connect an exhaust hood to an active chimney dryer vent vent flue or room ventilating ductwork Seek professional advice before connect...

Страница 7: ...re of the exhaust fan auto matically opens the flap blowing the inside air and cooking odors outside Recirculation mode Air is drawn through the grease filters and active charcoal filters The filtered air is then recirculated back into the kitchen through a vent at the top of the hood s chimney The active charcoal filters may be purchased from your Miele dealer or Miele s Technical Service Departm...

Страница 8: ...Guide to the hood 8 ...

Страница 9: ... to reset the grease filter timer after cleaning the grease filters see Cleaning and Care to show how long the grease filters have been in use see Operation Filter timers to change the number of hours counted by the grease filter timer see Operation Reprogramming the filter timers i Charcoal filter button The indicator above the charcoal filter button lights up when the charcoal filters need to be...

Страница 10: ...g If the appliance is not going to be used for a long period of time e g while vacationing it should be turned off 0 at the main power switch The next time it is turned on the hood will operate at the level previously used Joystick The joystick controls the fan power and overhead lighting Operation 10 ...

Страница 11: ...ould be used for a short period when frying or cooking food with a strong aroma Fan performance DA 362 75 The maximum air flow capacity is 425 cfm Factors such as narrow duct diameter and bends will affect this value DA 362 110 The maximum air flow capacity is 850 cfm Factors such as narrow duct diameter and bends will affect this value Level 1 operates at 40 capacity Level 2 operates at 60 capaci...

Страница 12: ... To cancel the Delayed Shut Down feature press the button again Turning off the fan Hold the joystick to the left until the fan shuts off and the fan power scale indicators go out Automatic Safety Shut Off The fan will turn off automatically 10 hours after the last movement of the joystick The lighting remains on Press the joystick once to the right to turn the fan back on again Overhead lighting ...

Страница 13: ...er see Operation Reprogramming the charcoal filter timer The charcoal filter indicator will light once the selected time has elapsed The charcoal filters must then be replaced and the charcoal filter timer must be reset To do this press the charcoal filter button for about 3 seconds The indicator will go out Checking the filter timers To check the percentage of time set already used Press the joys...

Страница 14: ...Press the Delayed Shut Down and the grease filter buttons at the same time The indicator for the grease filter and one of the fan power scale indicators will flash The indicators of the fan power scale show the programmed time 1st indicator from the left 20 hours 2nd indicator from the left 30 hours 3rd indicator from the left 40 hours 4th indicator from the left 50 hours Use the joystick to selec...

Страница 15: ...al filter and one of the fan power scale indicators will flash The indicators of the fan power scale show the programmed time 1st indicator from the left 120 hours 2nd indicator from the left 180 hours 3rd indicator from the left 240 hours 4th indicator from the left infinite Use the joystick to select the desired time Press it to the left for a shorter operating time to the right for a longer ope...

Страница 16: ...r and liquid dish soap applied with a soft sponge Wipe dry using a soft cloth Do not use too much water when cleaning the controls Water could penetrate into the electronics and cause damage Stainless steel Stainless steel surfaces can be cleaned using a non abrasive stainless steel cleaner To help prevent resoiling a conditioner for stainless steel can also be used Apply sparingly with even press...

Страница 17: ...filters Clean the filters by hand use a scrub brush in warm water with a mild detergent in a dishwasher place the filters vertically and diagonally in the lower basket If necessary adjust the upper basket Make sure that the spray arm can rotate freely Depending on the detergent cleaning the grease filters in a dishwasher may cause permanent discoloration of the filter surface Performance of the fi...

Страница 18: ...mall screwdriver into the slit along its edge to disengage it from the casing After returning the grease filters press the grease filter button for 3 seconds to reset the timer The indicator light will go out If the grease filters are cleaned before the grease filter timer has reached its maximum the grease filter button should be pressed for 6 seconds to reset the counter to zero Cleaning and car...

Страница 19: ...rcoal filters and fasten with the enclosed screws Return the grease filters Before using Program the charcoal filter timer see Operation Reprogramming the charcoal filter timer Replace the active charcoal filters when the charcoal filter indicator lights These filters should be replaced at least every 6 months or when they no longer absorb odors efficiently After replacing the charcoal filters pre...

Страница 20: ... attempt to change the bulbs until they have had sufficient time to cool down Do not touch the bulb surface Fingerprints or body oils deposited on the bulb will decrease the life of the bulb Follow the bulb manufacturer s instructions Remove the grease filter Loosen the bulb s fixing screw and slide it downwards Tighten the screw Turn the bulb to the left and pull it downwards Install the new bulb...

Страница 21: ...e Department U 1 800 999 1360 techserv mieleusa com V 1 800 565 6435 service miele ca When contacting the Technical Service Department please quote the model and serial number of your appliance These are shown on the data plate which is visible when the grease filter is removed After Sales Service 21 ...

Страница 22: ...22 ...

Страница 23: ...Installation Instructions ...

Страница 24: ...ren ensure that any plastic wrappings bags etc are disposed of safely and kept out of their reach Disposal of an old appliance Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Before discarding an old hood unplug it from the outlet and cut off its power cord to prevent hazards Caring for the e...

Страница 25: ...hind the grease filter match the household electrical supply before installing the hood If there is any question concerning the electrical connection of this appliance to your power supply please consult a licensed electrician or call Technical Service USA 1 800 999 1360 CDN 1 800 565 6435 WARNING THIS APPLIANCE MUST BE GROUNDED Important The hood comes equippped with a 5 ft 1 5 m power cord with ...

Страница 26: ...DA 362 75 Cut out dimensions A depth T min 1 9 16 40 mm is necessary in the rear of the cabinet Appliance dimensions 26 ...

Страница 27: ...DA 362 110 Cut out dimensions A depth T min 1 9 16 40 mm is necessary in the rear of the cabinet Appliance dimensions 27 ...

Страница 28: ...iele cooking appliances maintain the safety distances recommended by the cooktop manufacturer in their installation and operating instructions If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance Observe local building codes See Important Safety Instructions for further information 26 65 cm is recommended for all i...

Страница 29: ...e accessible after installation If the motor and fan assembly are not accessible assemble the ductwork and the electical connection before the installation Insert and align the hood from the bottom up in the cut out as seen in the illustration Secure the hood through the frame with 12 screws 3 5 x 16 mm Installation 29 ...

Страница 30: ...ace Reducing collar If using 5 125 mm ducting place the reducing collars into the exhaust connections and turn left to lock them in place Exhaust connection Connect the ductwork to the exhaust connection using appropriate measures for the type of ductwork being installed hose clamp duct tape etc Note A Y adapter is supplied with the DA 362 110 It may be used to feed the exhaust from both connectio...

Страница 31: ...our Miele dealer or the Technical Service Department For DA 362 75 1 conversion kit for recirculation mode 2 active charcoal filters For Da 362 110 2 conversion kits for recirculation mode 4 active charcoal filters Reducing collar The reducing collar must be used in recirculation mode Place the collars into the exhaust connections and turn left to lock them in place Do not insert the non return fl...

Страница 32: ...be made where the ducting ends for the installation of the recirculation vents b If installing the hood over an island or in a cabinet at ceiling height a suitable cut out has to be made in the front panel d The exhaust connection a and the recirculation vent b are joined together with a pipe or flexible duct c cut to size When installing the recirculation vents make sure that the slats point towa...

Страница 33: ...ront Tighten the screw with an allen wrench At the same time counter the joystick with a wrench Joystick extension The joystick can be extended for an easier reach Attach the lower part of the joystick to the extension with a spring washer Turn the m symbol to the front and screw in place with an allen wrench while using a wrench to counter the joystick base Place a spring washer between the joyst...

Страница 34: ... appliance to power read the Important Safety Instructions Plug in the power cord Before using the appliance remove the grease filters and remove the protective foil from the filter frame Insert the grease filters back into place Installation 34 ...

Страница 35: ...essary e g where narrower ducting has already been installed WARNING To reduce the risk of fire only use metal ductwork CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages Only use wide radius bends Tight bends reduce the air flow of the hood Use smooth or flexible...

Страница 36: ...e Important If the ductwork runs through rooms ceilings garages etc where temper ature variations exist it may need to be insulated to reduce condensation In some cases a condensate trap may also be required to collect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust outlet Air extracti...

Страница 37: ...37 ...

Страница 38: ...38 ...

Страница 39: ...39 ...

Страница 40: ...M Nr 06 191 500 00 Alteration rights reserved 1604 This paper was bleached without the use of chlorine ...