manualshive.com logo in svg
background image

Operating and installation instructions

Ventilation System
DA 229-2

To prevent accidents

V

and machine damage,
read these instructions

before

installation or use.

M.-Nr. 05 603 730

Содержание DA 229-2

Страница 1: ...Operating and installation instructions Ventilation System DA 229 2 To prevent accidents V and machine damage read these instructions before installation or use M Nr 05 603 730 ...

Страница 2: ...he power level 9 Delayed Shut Down 9 Turning off the fan 10 Turning the lighting on off 10 Grease filter timer 11 Checking the grease filter timer 11 Reprogramming the grease filter timer 12 Cleaning and Care Cleaning the casing 13 Grease filters 14 Changing the light bulb 16 After Sales Service Installation instructions Table of Contents 2 ...

Страница 3: ...is prop erly installed and grounded by a qualified technician To guarantee the electrical safety of this appliance continuity must exist be tween the appliance and an effective grounding system It is imperative that this basic safety requirement be met If there is any doubt have the electrical system of the house checked by a qualified electrician The manufacturer cannot be held responsible for da...

Страница 4: ...ve cooking surfaces un attended while in use Overheated food oil and grease can catch fire Do not use the hood without the grease filters in place Clean the grease filters regularly Dirty filters are a fire hazard Do not use a steam cleaner to clean the hood Steam could pene trate electrical components and cause a short circuit In areas subject to infestation by cockroaches or other pest keep the ...

Страница 5: ...National Fire Protection Association NFPA or the American Society for Heating Refrigeration and Air Condi tioning Engineers ASHRAE If in doubt consult an experienced profes sional WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner Be careful to prev...

Страница 6: ...Guide to the appliance 6 ...

Страница 7: ...ase filters see Cleaning and Care to show how long the grease filter has been in use see Operation Grease filter timer to change the number of hours counted by the grease filter timer see Operation Reprogramming the grease filter timer Delayed Shut Down This button activates the Delayed Shut Down feature The fan can be set to turn off automatically after either 5 or 15 minutes Fan power level butt...

Страница 8: ... hood comes equipped with a non return flap This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur When the hood is turned on the air pressure of the ex haust fan automatically opens the flap blowing the inside air and cooking odors outside Functional description 8 ...

Страница 9: ...oking Intensive setting Level 4 yellow indicator should be used for a short period when frying or cooking food with a strong aroma Fan performance The maximum air flow capacity is 625 cfm Factors such as narrow duct diameter and bends will affect this value Level 1 operates at 40 capacity Level 2 operates at 60 capacity Level 3 operates at 80 capacity Level 4 operates at 100 capacity Delayed Shut ...

Страница 10: ...r the last button was acti vated The lighting however will remain on Press the On Off button to turn the fan back on Turning the lighting on off The overhead lighting can be turned on and off independently of the fan Press the light button to turn on the lighting The light button indicator illuminates Press the light button again to turn off the lighting Operation 10 ...

Страница 11: ... filter but ton for about 3 seconds The indicator will go out Checking the grease filter timer To check the percentage of time al ready used Press the On Off button to turn the fan on Press the grease filter button The number of flashing pm indica tors show the percentage of pro grammed hours that have been used 1 indicator less than 25 2 indicators less than 50 3 indicators less than 75 4 indicat...

Страница 12: ...ore difficult Press the On Off button to turn off the fan Press the Delayed Shut Down and grease filter buttons at the same time The indicator for the grease filter and one of the pm indicators will flash The lit pm indicator shows the pro grammed time 1st indicator from the left 20 hours 2nd indicator from the left 30 hours 3rd indicator from the left 40 hours 4th indicator from the left 50 hours...

Страница 13: ...te into the electronics and cause damage Glass surfaces can be cleaned using glass cleaner Avoid cleaning agents containing soda ac ids or chlorides abrasive cleaning agents e g pow der or cream cleansers abrasive sponges e g pot scourers or sponges which have been previ ously used with abrasive cleaning agents These will damage the surface Stainless steel Stainless steel surfaces can be cleaned u...

Страница 14: ...e filter Clean the filters by hand use a scrub brush in warm water with a mild detergent in a dishwasher place the filters in the lower basket making sure that the spray arm is not blocked Depending on the detergent clean ing the grease filters in a dishwasher may cause permanent discoloration of the filter surface Performance of the filter will not be affected by this discoloration After cleaning...

Страница 15: ...river into the slit along its edge to disengage it from the casing After returning the grease filters press the grease filter button for 3 seconds to reset the timer The indi cator light will go out If the grease filters are cleaned be fore the timer has reached its maxi mum the grease filter button should be pressed for 6 seconds to reset the counter to zero Cleaning and Care 15 ...

Страница 16: ... until they have had sufficient time to cool down Do not touch the bulb surface Fin gerprints or body oils deposited on the bulb will decrease the life of the bulb Please follow the bulb manu facturer s instructions To change the halogen bulb first re move the lamp cover a Pull the bulb b out of its socket and replace with a new one Return the lamp cover a Never use the lighting without the lamp c...

Страница 17: ... Service Department USA 1 800 999 1360 techserv mieleusa com CDN 1 800 565 6435 service miele ca When contacting the Technical Service Department please quote the model and serial number of your appliance These are shown on the data plate which is visible when the grease filters are removed After Sales Service 17 ...

Страница 18: ...18 ...

Страница 19: ...Installation instructions ...

Страница 20: ...Electrical data Appliance dimensions Installation Retaining plates 28 Attaching the canopy 31 Inserting the non return flap 32 Electrical connection 33 Exhaust connection 33 Attaching the chimney extension 34 Attaching the chimney 35 Air extraction Table of Contents 20 ...

Страница 21: ...ely and kept out of the reach of children Dan ger of suffocation Disposal of an old appliance Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Before discarding an old appliance unplug it from the outlet and cut off its power cord and remove any doors to prevent hazards See the Warning and Saf...

Страница 22: ...Installation accessories 22 ...

Страница 23: ...C for addi tional stability of the chimney g Lower retaining plate A secures the canopy and the motor assembly 6 screws 5 x 60 mm 10 large headed screws 5 x 40 mm S8 wall anchors included in the pack aging are not for use in USA CDN 2 M 6 locking nuts for securing the motor assembly 4 screws 3 9 x 7 5 mm for securing the chimney and the chimney extension CAUTION During the installation process ple...

Страница 24: ...plate A against the wall so that the marks are visible through the holes of the plate see Installation Retaining plate A Draw a line around the plate s perim eter then set aside the plate Make a cutting line 3 76 mm above and 3 76 mm below the outline of plate A Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder Mark a vertical cutting line alo...

Страница 25: ...d on the data plate located behind the grease fil ters match the household electrical supply before installing the hood If there is any question concerning the electrical connection of this appliance to your power supply please consult a licensed electrician or call Miele s Tech nical Service Department USA 1 800 999 1360 CDN 1 800 565 6435 WARNING THIS APPLIANCE MUST BE GROUNDED Important The hoo...

Страница 26: ...Appliance dimensions 26 ...

Страница 27: ...ded for all in stallations to allow for optimum work space under the hood Read the entire installation procedures and determine height S before begin ning the installation If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than appliance height H Standard unit height H DA 229 2 29 1 8 42 1 8 740 1070 mm To fit the chimney distance...

Страница 28: ... be used if the distance between plate A and plate B is greater than 14 3 8 365 mm Attaching the retaining plates to the wall Before fitting the retaining plate draw a vertical line centrally above the cooktop on the rear wall Mark measurement S from the cooktop surface upwards see Appli ance dimensions This marks the height of the lower rim of the hood Installation 28 ...

Страница 29: ...ensions Lightly secure retaining plate A into position using 5 x 40 mm screws through the two holes and use the notches to align with the center line Drill 6 more 1 8 3 mm holes through the now fitted retaining plate Screw four 5 x 40 mm screws into the upper and lower set of holes to se cure retaing plate A Installation 29 ...

Страница 30: ... with two 5 x 40 mm screws Retaining plate C Retaining plate C should only be used if dimension Y is greater than 14 3 8 365 mm It provides additional stabil ity for the chimney extension At a maximum distance of 14 3 8 365 mm from the ceiling hold retain ing plate C against the wall and use the notches to align it with the center line Mark the two drill holes Drill two 1 8 3 mm holes into the wal...

Страница 31: ...ews 5 x 60 mm Adjusting the canopy If the canopy is not perpendicular to the wall it can be adjusted Loosen the two securing screws a Slightly loosen the adjusting screws b Adjust the canopy so that it is level and perpendicular to the wall Tighten the adjusting screws b and the securing screws a Installation 31 ...

Страница 32: ...exhaust ducting If 5 125 mm ex haust ducting is used the reducing collar must be fitted into the exhaust connection on the motor see Air ex traction Attaching the motor assembly First loosely screw the two locking nuts onto the threaded bolts on re taining plate A Leave a gap of 1 8 3 mm for hang ing the motor on Fit the motor assembly onto the hooks on retaining plate A and slide down behind the ...

Страница 33: ...into the receptacle left of the motor assem bly Insert the 6 prong connector into the receptacle right of the motor assem bly Secure the cords with the ties as shown above Plug in the power cord Exhaust connection Conect the ductwork to the exhaust connection using whatever means are appropriate for the type of ductwork being installed hose clamp duct tape etc Direct the duct through the back wall...

Страница 34: ...ll make installing the chimney extension easier Be careful of sharp edges Pull the chimney extension slightly outwards and snap over the upper retaining plate B Secure the chimney extension to the upper retaining plate with two 3 9 x 7 5 mm screws Fold the protective shield at the top Remove the adhesive backing from the shield Stick the shield to the chimney exten sion so that it is smooth and fl...

Страница 35: ...he canopy Align and adjust the chimney Remove the protective shields Secure the chimney to retaning plate A on both sides with two 3 9 x 7 5 mm screws Remove the protective foil from the canopy If the chimney is not tall enough an optional chimney extension can be ordered See Appliance dimen sions Before using the appliance remove the grease filter and remove the pro tective foil from the filter f...

Страница 36: ... also reduces the air extraction efficiency Noise levels of the hood will increase if flat ducts or round ducts of less than 6 150 mm in diameter are used WARNING To reduce the risk of fire only use metal ductwork CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air out side Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garage...

Страница 37: ...essary As duct diameter decreases the hood s performance and sound levels will be affected Important If the ductwork runs through rooms ceilings garages etc where tempera ture variations exist it may need to be insulated to reduce condensation In some cases a condensate trap may also be required to collect and evapo rate any condensate which may occur When installing a condensate trap ensure that ...

Страница 38: ...38 ...

Страница 39: ...39 ...

Страница 40: ...Alteration rights reserved 000 CDN 1801 This paper consists of cellulose which has been bleached without the use of chlorine ...