First loosely screw the two self lock-
ing nuts onto the threaded bolts on
retaining plate A. Leave a small gap
of 3 – 5 mm for hanging the motor on
afterwards.
Fit the motor unit onto the hooks on
retaining plate A and slide down be-
hind the nuts.
Tighten the nuts.
Control unit
(only when operating with an external
fan)
If a 150 mm ø exhaust ducting has to
be used, adapt the connection by
cutting it off at the join with a sharp
knife (see illustration).
The exhaust connection does not
need adapting if 125 mm ø ducting
is being used.
It has an integrated non-return flap.
Fit the motor unit onto the hooks on
retaining plate A and slide down be-
hind the nuts.