manualshive.com logo in svg
background image

Operating and installation instructions

Cooker Hoods
DA 226-2,
DA 227-2,
DA 229-2, DA 229-2 EXT

It is 

essential

 to read these

operating instructions before

GiWO

installing or using the machine
to avoid the risk of accidents or 
damage to the machine.

 M.-Nr. 05 609 500

Содержание DA 226-2

Страница 1: ...tructions Cooker Hoods DA 226 2 DA 227 2 DA 229 2 DA 229 2 EXT It is essential to read these operating instructions before GiWO installing or using the machine to avoid the risk of accidents or damage to the machine M Nr 05 609 500 ...

Страница 2: ...switch the lighting off 12 Filter operating hours counter 13 Reading the filter operating hours counter 13 Altering the filter operating hours counter 14 Cleaning and care Housing 15 Grease filters 16 Changing a halogen light bulb 18 After Sales Service 19 Appliance dimensions 20 Installation Assembly parts 22 Retaining plates 24 Canopy 26 Motor unit 27 Control unit 28 Electrical connection 29 Air...

Страница 3: ...ren Danger of suffocation Rather than just throwing these materials away please ensure they are offered for recycling Disposal of your old appliance Old appliances may contain material which can be reclaimed or recycled Please contact your dealer your local waste collection centre or scrap mer chant about potential recycling schemes Ensure that the appliance presents no danger to children while be...

Страница 4: ...must correspond in order to avoid risk of damage to the appliance Consult a qualified electrician if in doubt The electrical safety of this ap pliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national regulations It is most import ant that this basic safety requirement is tested by a qualified electricia...

Страница 5: ...are always covered by a pan Otherwise flames could be drawn up by the suction of the cooker hood parts of which could then be damaged Always switch the cooker hood on when using the hob Other condensation may collect in the hood which could cause corrosion When cooking with oil or fat chip pans and deep fat fryers etc do not leave the pans unattended Never leave an open grill unattended when grill...

Страница 6: ... have different minimum safety distances to the cooker hood select the higher dis tance Safety regulations prohibit the fit ting of a cooker hood over solid fuel stoves All ducting pipework and fittings must be of non flammable ma terial These can be obtained from the Miele Spare Parts department or from builders merchants The appliance must not be con nected to a chimney or vent flue which is in ...

Страница 7: ... outside wall vents or by other technical measures such as ensuring that the extractor can only be switched on when the heating ap pliance is switched off or vice versa N B The overall ventilation condition of the dwelling must be taken into ac count If in any doubt the advice of a competent builder or for gas a Corgi installer must be sought Appliances with external fans For appliances with an ex...

Страница 8: ...Guide to the appliance Guide to the appliance 8 ...

Страница 9: ...e to show how long the active charcoal filters have been in use see section on Operation Filter operating hours counter to alter the number of hours counted by the filter operating hours counter see section Operation Altering the filter operating hours counter i Touch control for the run on function This control activates the run on option The fan is switched off automatically after either 5 or 15...

Страница 10: ...off No exchange of room air and outside air can take place When the cooker hood is switched on the non return flap opens for the cooking vapours to be blown directly outside with an external fan The EXT models are designed to be connected to an external fan located outside the room The external fan is connected to the cooker hood by means of a control cable and is operated by the control panel on ...

Страница 11: ...trol lower setting Depending on the intensity of cooking vapours levels I to III green indica tor lamps are usually sufficient for nor mal cooking Intensive setting When frying or cooking food with a strong aroma you may wish to select the Intensive setting yellow indicator lamp for a short period Run on option If the air still needs to be cleared after cooking the cooker hood can be set to contin...

Страница 12: ...tched on press and hold the hob illumination control in The brightness will gradually dim until you release the control Press the control in again to increase the brightness to the level required and then release it If you keep the control pressed in the brightness will continually go brighter and then dimmer To switch the lighting off Briefly press the hob illumination control to switch the light...

Страница 13: ...s The indicator lamp will go out Reading the filter operating hours counter Before reaching the end of the period set you can check the percentage of time set which has already been used up Use the On Off touch control to switch the fan on Press the grease filter touch control One or several of the indicator lamps for the touch controls will flash The number of flashing lamps shows the percentage ...

Страница 14: ...ore difficult Use the On Off touch control to switch the fan off Press the run on option touch control and the grease filter touch control at the same time The indicator lamp for the grease filter touch control and one of the touch control lamps will flash The touch control lamps show the time which has been set 1st lamp from the right 20 hours 2nd lamp from the right 30 hours 3rd lamp from the ri...

Страница 15: ...glass Avoid cleaning agents containing soda acids or chlorides abrasive cleaning agents e g pow der cleaners or cream cleaners abrasive sponges e g pot scourers or sponges which have been pre viously used with abrasive cleaning agents These will damage the surface ma terial E Cloth A microfibre E Cloth is available from the Miele UK Spare Parts Department Part number 98013530 which is suit able fo...

Страница 16: ...ean the filters by hand with a nylon brush warm water with a little washing up liquid in a dishwasher place the filters with the short side upright in the lower basket ensuring the spray arm is not obstructed Depending on the cleaning agent used cleaning the grease filters in a dishwasher can cause permanent discolouration to the surface of the filters However this will not affect the func tioning...

Страница 17: ... them Do not let them drop on to the hob below After replacing the grease filters press the grease filter touch control for approx 3 seconds to re set the operating hours counter The indicator lamp will go out If the grease filters are cleaned be fore the operating hours counter has reached its maximum the grease fil ter touch control should be pressed for approx 6 seconds to reset the counter to ...

Страница 18: ...n changing ha logen lamps They get very hot dur ing use and remain hot for some time after being switched off Do not touch the surface directly when changing a lamp as grease particles from your fingers will ad here to the surface and damage it Please follow the manufacturer s in structions To access the halogen light bulb first remove the lamp cover b Pull the old halogen light bulb c out of the ...

Страница 19: ...Department see back cover for address When contacting the Service Depart ment please quote the model and ser ial number of your appliance These are shown on the data plate which is visible when the grease filters are removed Please note that telephone calls may be monitored and recorded to improve our service After Sales Service 19 ...

Страница 20: ...Appliance dimensions Appliance dimensions 20 ...

Страница 21: ...ace When deciding dimension S ensure that the minimum specified safety dis tance between the hob cooker and the cooker hood is maintained If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than ap pliance height H Appliance height H DA 226 2 227 2 229 2 229 2 EXT 740 1070 mm To fit the tower distance A between the top of the tower...

Страница 22: ...Installation Assembly parts Installation 22 ...

Страница 23: ...e B for secur ing the extension piece g Middle retaining plate C for addi tional stability of the tower h Lower retaining plate A for secur ing the canopy and the motor unit 2 screws 5 x 60 mm and 2 x S 8 R60 plugs for securing the re taining plates and the canopy 10 large headed screws 5 x 40 mm and 10 x S 8 plugs for securing the retain ing plates 2 M 6 locking nuts for securing the motor unit c...

Страница 24: ...fitting the retaining plate draw a vertical line centrally above the hob on the back wall Mark measurement S from the hob surface upwards see Appliance dimensions This marks the height of the lower rim of the cooker hood Retaining plate A Drill two 8 mm ø holes one at S 75 mm and one at S 400 mm on the centre line for the retaining plate see Appliance dimensions Insert S8 plugs Installation 24 ...

Страница 25: ...d then se cure the retaining plate in position using four 5 x 40 mm screws Press two S8 R 60 plugs into both middle holes Retaining plate B Hold retaining plate B to the wall and push up until it is directly below the ceiling Use the notches to align it horizontally with the middle line Mark the 2 drill holes on the wall Drill two 8 mm ø holes into the wall and press the S8 plugs into the holes Sc...

Страница 26: ...from the ceiling hold retaining plate C against the wall and use the not ches to align it with the middle line Mark the two drill holes Drill two 8 mm ø holes into the wall and press the S8 plugs into the holes Screw on retaining plate C with two 5 x 40 mm screws Canopy Hang the canopy on the angle brackets on retaining plate A Secure the canopy with two 5 x 60 mm screws Installation 26 ...

Страница 27: ...rews b securely Motor unit not when operating the external fan If a non return flap is not present in the venting system the non return flap supplied must be fitted into the exhaust connection in the motor unit The flaps must open upwards The cooker hood is designed to take ø 150 mm exhaust ducting If 125 mm ø exhaust ducting has to be used the reducing collar needs to be fitted into the exhaust c...

Страница 28: ...d the nuts Tighten the nuts Control unit only when operating with an external fan If a 150 mm ø exhaust ducting has to be used adapt the connection by cutting it off at the join with a sharp knife see illustration The exhaust connection does not need adapting if 125 mm ø ducting is being used It has an integrated non return flap Fit the motor unit onto the hooks on retaining plate A and slide down...

Страница 29: ... Connect the six pole plug into the coup ling on the right of the motor unit or control unit Secure the cable in the cable clamps shown For appliances connected to an ex ternal fan model designation EXT Connect the control unit and the ex ternal fan with the connection cable and the six pole plug Connect the appliance to the mains via a fused spur or fused socket as appropriate Before connecting t...

Страница 30: ... See section Connection for air ex traction Extension piece An extension piece allows the cooker hood to be fitted at varying distances from the ceiling see section appliance dimensions Before fitting the extension piece remove the protective foil Bend the top hanging retainers ap prox 45 inwards This makes fitting easier Pull the extension piece slightly out wards and push over the upper re taini...

Страница 31: ...ld the protective sheet at the top Remove the protective foil from around the sticking points Stick the protective sheet to the ex tension piece so that it is smooth at the sides and flush at the bottom Fitting the tower Before fitting remove the protective foil Hold the main tower gently apart and fit it over the extension piece Then slide the chimney piece down approx 2 cm into the canopy Adjust...

Страница 32: ... with 2 screws 3 9 x 7 5 mm Remove the protective foil from the canopy Before using the appliance for the first time take the grease filter out and remove the protective foil from the filter frame Then replace the filter Installation 32 ...

Страница 33: ... level of the cooker hood would increase and extraction would be less effi cient Only reduce the diameter of the duct ing if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable ma terials for extraction connection Where ducting i...

Страница 34: ...be addressed The exhaust ducting will need to be suitably insu lated Condensate trap In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection Connection for air ext...

Страница 35: ...in stallation depending on country an ad ditional means of disconnection must be provided for all poles For extra safety it is advisable to install a residual current device RCD with a trip current of 30 mA in accordance with DIN VDE 0664 VDE 0100 Section 739 Do not connect via an extension lead Important UK If the appliance is fitted with a non re wireable plug BS 1363 UK and the socket outlets a...

Страница 36: ...een and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth sym bol z or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or col oured black For U K IRL ZA The wire which is coloured brown must be connected to the terminal which is marked with the letter L or col...

Страница 37: ...rical safety C Tick Mark Electrically suppressed according to AS NZS 1044 Extraction power according to EN 61591 Extraction system ø 150 mm Level I 220 m3 h Level II 335 m3 h Level III 440 m3 h Intensive level 640 m3 h Extraction system ø 125 mm Level I 210 m3 h Level II 305 m3 h Level III 405 m3 h Intensive level 590 m3 h Unrestricted 690 m3 h For EXT models the rated load and extraction power wi...

Страница 38: ......

Страница 39: ......

Страница 40: ...Alteration rights reserved 44 000 GB IRL AUS NZ 1301 This paper consists of cellulose which has been bleached without the use of chlorine ...

Отзывы: