Service and repair work should only be carried out by suitably qualified persons in
accordance with all appropriate local and national safety regulations.
Flow meter fitting
The module 7 flow meter is required.
Procedure:
^
Disconnect the machine from the mains.
^
Connect the flow meter to the stopcock (3/4" threaded union).
^
Take care to check the direction of flow.
^
Connect the water intake hose, Fig. 1, or Y-piece, Fig. 2.
^
Remove the electrical connection cover plate from the rear of the machine.
^
Connect the flow meter in accordance with the wiring diagram.
^
Refit the electrical connection cover plate.
^
Check the installation for leaks.
^
Carry out a check for correct operation in accordance with the "Module 7 flow meter fitting"
instructions.
M.-Nr. 06 258 810