Weld

Pin

1. If “B” Stop is used, seat weld pin firmly

against stop.

2. Loosen these adjustment screws.

3. Slide the Leg / Foot assembly until

weld pin flange extends 1/8"- 3/16"

beyond foot.

4. Retighten adjustment screw.

Adjustable

Leg /Foot

1/8"- 3/16" Protrusion

“B”

Stop

(optional)

“B”

Collet

(inside

Protector)

Collet

Protector

Collet

Protector

Insert

MIDWEST FASTENERS

800-852-8352

MIDWEST FASTENERS

800-852-8352

Remove the controller, cables and weld gun from the shipping packaging.

Connect the Cable connectors to the controller as marked: “CD” or “CUPHEAD”
depending on the fastener type to be welded.

NOTE:

All cables should be

laid out straight or in large loops.

CD-2T WELD GUN

SETUP

CUPHEAD PINS

CD-2T WELD GUN

SETUP

INSULATION PINS

WITH

COLLET PROTECTOR

Cuphead

Pin

1. Place POSI-Weld magnetic chuck in gun shaft and

retighten set screw.

2. Place Cup Head Pin on magnetic chuck.

NOTE:

A) When welding, maintain correct pressure

on gun (approximately 1/8" of gun spring.)

B) When welding through Foil Faced Insulation (FSK),

always use Cuphead Pins

with

 paper washer installed.

POSI-Weld

Magnetic

Chuck

PARTS

MIDWEST FASTENERS INC.

SETUP

CDWG-201-35