Midtronics MSP-070C Скачать руководство пользователя страница 7

MSP-070C Battery Maintainer

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

7

Connections & Controls

Product Specifications

Operating Parameters

Input Voltage

110V – 240V

~

, 50 – 60 Hz, 12A max.

Output 1

14.4VDC max., 70A max.

Charge Cables

 

2m (Standard)

 

3m

 

5m

Power Cord
Accepts locking C13 connector for region-specific power 

cables:

 

United States: EMA 5-15 termination, rated at 15A/125V 

UL CSA

Applications

 

Automotive

 

Group 31

 

Heavy-Duty

 

Commercial 4D/8D

 

Power Sports

Battery Chemistries

 

Lead acid

 

EFB

 

AGM

CCA Range

 

100 – 2000 CCA

Dimensions
(without handle or base)

 

Height: 4.80 in (12.19 cm)

 

Width: 13.1 in (33.27 cm)

 

Length: 12.0 in (30.48 cm)

 

Weight:18 lbs

Safety

 

UL1236, IEC 60335

EMC

 

EN61000-6-4 (Emissions) CISPR 11 Class A

 

EN61000-6-2 (Immunity)

 

EN61000-3-2 (Harmonics)

 

EN61000-3-3 (Flicker)

 

CEC, California Energy Commission

Protection Features

 

Reverse polarity

 

Battery voltage too low 

(<5.5V)

 

Non-12V battery 

connection

 

Clamp high temperature 

detection

 

Clamp connection

Error Codes

Error codes are transmitted via the red LED on the side of the 

charger. The number of flashes correspond with the error code 

number (Example:  Two [2] flashes = Error Code 02)

Code

Description

Action

01

Reverse polarity

Correct clamp connections to 

battery 

(

Red

 to + / Black to –)

02

Connection problem

Correct connections & restart 

charge sequence

03

Non 12V battery 

connected

Connect to 12V

04

Battery voltage too 

low (<5.5V)

Battery deeply discharged or may 

be damaged. consider replacing 

battery

08

Internal current failure

Switch unit off then on again. If fan 

is not running call for service.

09

Internal voltage failure Switch unit off then on again. If fan 

is not running call for service.

10

Internal temperature 

too high

Switch unit off then on again. If fan 

is not running call for service.

11

Cable temperature 

sensor open

Replace charge cable:  

SO, (Tsensor = open)

12

Cable temperature 

sensor short

Replace charge cable: 

SS, (Tsensor = short)

13

Charge cable (Vab)

Replace clamp or charge cable

14

Sensing cable (Vcd)

Replace clamp or charge cable

15

Battery temperature 

exceeds thermal limit

Battery replacement recommended, 

unsafe to charge

16

Battery temperature 

below thermal limit

Frozen battery, may not recover

20

Unit internal error

Call for service

Содержание MSP-070C

Страница 1: ...USER GUIDE MSP 070C 70A Battery Maintainer October 2017 167 000757EN A...

Страница 2: ...eparing To Charge The Battery 3 Grounding Power Cord Connections 4 Charger Location 4 DC Connection Precautions 4 Installing The Battery 5 Removing the Battery 5 Maintenance Storage 5 Locking Power Co...

Страница 3: ...sary See paragraph 4 2 1 13 Have a damaged cord or plug replaced immediately 1 14 Do not expose the charger to rain or snow 2 Personal Precautions 2 1 The MSP series chargers are not to be used by pe...

Страница 4: ...ion cord are the same number size and shape as those of the plug on the charger b that the extension cord is properly wired and in good electrical condition c that the wire size is large enough for th...

Страница 5: ...t the NEGATIVE BLACK charger clamp to the free end of the cable 8 5 When disconnecting the charger always do so in the reverse se quence of the connecting procedure break the first connection while st...

Страница 6: ...rolling unit Voltage 14 4v 13 6v 13 2v Cooling Vent Side View Cooling Fans On Off Switch C14 Power Cable Plug in Locking Power Cord Always use the red tabs on each side of the power cord connector to...

Страница 7: ...tted via the red LED on the side of the charger The number of flashes correspond with the error code number Example Two 2 flashes Error Code 02 Code Description Action 01 Reverse polarity Correct clam...

Страница 8: ...he cable assembly SERVICE To obtain service contact Midtronics at 866 592 8052 Have your model and serial numbers ready This first step is critical as we will trouble shoot the problem s over the phon...

Отзывы: