17
•
Chapter 3: Test Preparation
Inspecting the Battery
Before starting the test visually inspect the battery for:
• Cracked, buckled, or leaking case. If you see any of these defects, replace the battery.
• Corroded, loose, or damaged cables and connections. Repair or replace them as
needed.
• Corrosion on the battery terminals, and dirt or acid on the case top. Clean the case and
terminals using a wire brush and a mixture of water and baking soda.
• Low electrolyte level. If the electrolyte level is too low, add distilled water to fill up to 1/2
above the top of the plates and fully charge the battery. Do not overfill.
• Corroded or loose battery tray and hold-down fixture. Tighten or replace as needed.
Testing Out-of-Vehicle
The preferred battery test location is in the vehicle. However, if you plan to test out of the vehicle:
• Always disconnect the negative cable from the battery first and reconnect it last.
• Always use a carry tool or strap to lift and transport the battery.
CAUTION:
When testing side-post or group 1 batteries, always test using lead terminal adapters
provided with the EXP; do not test at the battery’s steel bolts. To avoid damage, never use a wrench
to tighten the adapters more than 1/4 turn. Failure to properly install lead terminal adapters, or using
adapters that are dirty or worn, may cause false test results.
Testing In-Vehicle
The preferred test position is at the battery posts. If you must test at a remote-post location, it should
have both a positive and negative post. Otherwise, you must remove the battery and perform an out-
of-vehicle test.
At the start of the test, make sure all vehicle accessory loads are off, the key is not in the ignition, and
the doors are closed.
Connecting the Battery Test Cable
CAUTION:
Do not connect the EXP to a voltage source greater than 0 Vdc.
Connect the battery test cable to the EXP by first aligning the cable connector’s 6 pins with the holes
on top of the EXP. Firmly insert the connector and tighten the locking ring.
Connect the clamps to the EXP: the red clamp to the positive (+) terminal and the black clamp to the
negative (–) terminal.
Chapter 3: Test Preparation
Содержание intellect EXP-1000
Страница 2: ......