15
During charging, the GR-1 keeps the user informed by displaying the
following information: charging voltage, charging current, remaining
time to charge, charging mode (Manual Mode), and the amount of
charge put back into the battery (shown in Ah).
CHARGE COMPLETION
The manual charge session is complete when the selected, remaining time to charge goes to zero. The GR-1
will measure and record the final parameters of the battery.
Details can be found on the print-out.
When the measurement is complete, the GR-1 will alert the user with
an audible alarm and will display the following information: battery
voltage, available starting current in CCA, total charging time,
charging mode, and the final amount of charge put back into the battery
(shown in Ah).
Details can be found on the print-out.
The audible alarm will sound every 30 seconds, until the user presses the STOP button.
CONTINUOUS CHARGING
If Continuous Charge is selected, the GR-1 will analyze the battery
briefly, display the measured voltage and available starting current
in CCA and then begin charging at the selected levels.
The user must press the STOP button to stop the charging session.
During charging, the GR-1 keeps the user informed by displaying
the following information: charging voltage, charging current,
charging mode (Manual Mode), and the amount of charge put
back into the battery (in Ah).
CHARGE COMPLETION
The Continuous Charge session is complete when the STOP button is pressed. The GR-1 will measure
and record the final parameters of the battery.
Details can be found on the print-out.
When the measurement is complete, the GR-1 will sound an audible
alarm and display the following information: battery voltage,
available starting current in CCA, charging mode, and the final
amount of charge put back into the battery (shown in Ah).
The audible alarm will sound every 30 seconds until the user presses the STOP button again, or
disconnects the charger clamps from the battery.
Note: If the 60 Amp mode is selected for manual or continuous charging, see GR-1 Operating Steps (5),
the GR-1 will automatically switch the output to the 30 Amp mode after one hour.
3. JUMP START VEHICLE
This mode makes high output current available to boost charge an
in-vehicle battery as well as assist in starting the engine.
The GR-1 will prompt the user to begin “boost charging” the battery.
This will greatly improve the ability to start the engine when it’s
time to crank the engine.
The GR-1 informs the user that the battery is being “boost charged”.
This process will take less than a minute.
When the GR-1 determines the optimal time to crank the engine,
it will inform the user. The user can crank the engine for up to
5 seconds.
The GR-1 will inform the user when the jump start function is
complete.
14.50V 35.5A 1:02:34
Manual Mode Ah: 0.7
13.79V 526CCA 1:20:34
Manual Mode Ah: 57.7
Analyzing Battery…
5.27V 12CCA
Battery Test Information
14.50V 9.5A -:--:--
Manual Mode Ah: 0.7
Select Mode
Jump Start Vehicle
13.99V 637CCA -:--:--
Manual Mode Ah: 57.2
Press (
)
to begin boost
charge………………….
Boost charging battery,
Wait for beep to crank…
*** Crank Engine Now ***
Jump Start Complete!
Press Stop Key…