![Midtronics EBT-965P Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/midtronics/ebt-965p/ebt-965p_user-manual_1792898011.webp)
www.midtronicseurope.com
2 – Car
EBT-965P
11
Test Results - Battery
Cranking Health
Battery meets or exceeds
required standards. Test
again in 90 days or at
next service opportunity.
Rated: 575 CCA
Measured: 599 CCA
Test Results - Battery
Reserve Health
OK
The battery has sufficient
reserve health to
provide power for the
electronics systems in the
vehicle.
System Test
1.
Select System Test displayed at the bottom of the screen to continue to the System Test.
1.
Start the vehicle's engine and let it idle.
2.
Ensure all accessories (High Beam headlights/ventilation blower etc.) are off and select Next.
The analyzer tests the alternator output.
3.
When prompted, rev and hold the engine to between 2000 to 3000 rpm.
The analyzer tests the alternator output again.
4.
When prompted Idle the engine and and select Next.
5.
Turn on the high beam headlights and ventilation blower.
6.
Select Next.
The analyzer tests the alternator output.
7.
When prompted, rev and hold the engine to between 2000 to 3000 rpm.
The analyzer tests the alternator output again.
8.
When prompted Idle the engine and and select Next.