5. If the width of the door is wider than the length of the air curtain, please use two or more assemblies. In
this situation, please make sure the distance is about 25/32 in~1 ft.
37/64
in.
6. When installing the air curtain, please make sure the air curtain is hung on the wall plate and the wall
cannot leave space.
7. The distance between the air curtain and the doorway should not be smaller than
1⅜
in.
8. Please make sure of the level to install.
9. When installing, please make sure the distance between air outlet and the ground is more than
7 ft 6½ in.
9. The Control and Use of Air Curtain
1.
Installation of the magnetic door switch (Picture 6-1, 6-2). The air curtain can be controlled by this
switch.
Part A goes on the door frame and Part B goes onto the door itself. As long as the magnets in both parts
work when close to each other when the door is closed, the magnetic door switch has been properly
installed. When the door is closed and both parts are close to each other, the air curtain will not be active
and will be off. (Picture 6-1) Once the door is open and both parts are no longer near each other, the air
curtain gets activated and will turn on. (Picture 6-2)
Picture 6-1 Picture 6-2
2. With the buttons on the air curtain itself you can switch between two speeds on the air curtain control
circuit (Picture 7-1, 7-2); once you have pressed the ON button please press LO or HI, then after
obtaining the appropriate air speed, press the OFF button to stop.
Picture 7-1 Picture 7-2