DC-GFP 100 Instructions

 

 

 

 

MNDC-GFP100 

Ground Fault Protector

 

100 amp 150VDC panel mount Dual DC ground fault protector (NRTL listed breaker assy) 
 
All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. 

All MidNite circuit breakers hold 100% rated current independent of ambient temperature. 

 
The MNDC-GFP100  can be used in the following ways. 
1 pv array breaking pv - and + using the 1 amp pole as the trip source  
1 pv array breaking pv – and + using the classic to shunt trip the device  
2 pv arrays breaking just the + using the 1 amp pole as a trip source  
2 pv arrays breaking just the + using the classic to shunt trip the device 
 

MIDNITE SOLAR INC.   17722 67

TH

 

 AVE NE  ARLINGTON, WA 98223 

Email

[email protected] 

PH: 360-403-7207   FAX: 360-691-6862

  

 

Содержание DC-GFP 100

Страница 1: ...current independent of ambient temperature The MNDC GFP100 can be used in the following ways 1 pv array breaking pv and using the 1 amp pole as the trip source 1 pv array breaking pv and using the classic to shunt trip the device 2 pv arrays breaking just the using the 1 amp pole as a trip source 2 pv arrays breaking just the using the classic to shunt trip the device MIDNITE SOLAR INC 17722 67TH ...

Страница 2: ...wiring diagram you will notice that part of the DC GFP is a high current breaker Connected in series with the GFP is yet another high current DC breaker It is a common mistake to think the second breaker is unnecessary NEC2008 requires a DC GFP on all systems whether mounted on the roof top of a residence or not The NEC also does not allow the DC GFP to be the PV disconnect When the DC GFP is turn...

Страница 3: ...EAKER MNDC GFP 100 SINGLE ARRAY POSITIVE AND NEGATIVE P V LINES DISCONNECTED UPON 1 AMP GROUND FAULT BATT NEG T CARPENTER 3 5 13 1 0 0 1 ON 100 80 ON 100 SHUNT TRIP GROUND BATTERY NEGATIVE PV ARRAY CLASSIC MPPT CHARGE CONTROLLER MNDC GFP 100 PV POS PV NEG PV POS PV INPUT BREAKER MNDC GFP 100 SINGLE ARRAY POSITIVE AND NEGATIVE P V LINES DISCONNECTED BY CLASIC S BUILT IN GFP BATT NEG AUX 1 T CARPENT...

Страница 4: ...NEG MNDC GFP 100 TWO ARRAYS TWO CONTROLLERS P V POSITIVE DISCONNECT ONLY SELF TRIPPING ON 1 AMP GROUND FAULT T CARPENTER 3 5 13 1 0 0 1 ON 100 80 ON 100 SHUNT TRIP GROUND BATTERY NEGATIVE PV ARRAY CLASSIC MPPT CHARGE CONTROLLER MNDC GFP 100 AUX 1 PV POS PV NEG PV POS PV INPUT BREAKER PV POS PV NEG CLASSIC MPPT CHARGE CONTROLLER PV POS PV INPUT BREAKER BATT NEG BATT NEG MNDC GFP 100 TWO ARRAYS TWO ...

Отзывы: