Reference Oscillator   

4  Initiate transmit on any channel. Measure transmitted RF carrier frequency  

without modulation and, if necessary, adjust REFERENCE OSCILLATOR X701  

for carrier frequency to within 

±

30Hz of channel frequency. 

 

PA MODULE ALIGNMENT 

The 70 -0671 should be adjusted to have a 6 MHz channel spread (8 MHz C-Band) 

at 110W. To do so : 

 

1  Change the TX test frequency to the desired frequency.  

 

2  Activate transmit mode and measure RF power at Antenna connector J502. 

Set RF output power to 110W at J502 using the programmer. 

 

 

MODULATOR ALIGNMENT  

Modulation Limiting   

Disconnect the hand microphone from its front panel Mic Jack J302.  

Apply 3Vrms of 1000Hz signal to pin 1 of Mic Jack J302, then initiate transmit.   

 

Measure total carrier deviation and, if needed adjust modulation limiting to obtain 

 

±

5KHz (wide) or 

±

2.5KHz (narrow) using the programmer. 

 

Microphone Gain 

3  No alignment for Microphone gain is required. 

 

CTCSS/DCS 

4  Remove the 1KHz audio signal from Mic Jack J302. 

 

5  Add 250.3Hz CTCSS tone to the transmit test by testing frequency using the  

   programmer. 

 

6  Adjust CTCSS deviation to 

±

750 Hz 

±

 10 Hz (wide) or 

±

 375 Hz 

±

 10 Hz   

   (narrow) deviation using the programmer. 

 

7  Change 67.0 Hz CTCSS tone to the transmit test b y testing frequency using in the  

   programmer. 

Содержание 70-0671

Страница 1: ...o only one side of the speaker and chassis ground Normally voltage measurement will be half of true values 5 Turn the radio on Push on and Push off switch set the VOLUME control to a mid position Conn...

Страница 2: ...ODULATOR ALIGNMENT Modulation Limiting 1 Disconnect the hand microphone from its front panel Mic Jack J302 Apply 3Vrms of 1000Hz signal to pin 1 of Mic Jack J302 then initiate transmit 2 Measure total...

Страница 3: ...waveform shown in Figure 2 1 11 Change 250 3 Hz CTCSS tone to the transmit test by testing frequency using the programmer Carefully adjust RV401 for 750 Hz 10 Hz w ide or 375 Hz 10 Hz narrow deviatio...

Страница 4: ...or L802 unless approp riate test equipment is available for performing the Noise Blanker Tuning steps below Normally these coils are tuned for optimum sensitivity as are L803 and L804 then are retune...

Страница 5: ...n The SINAD reading should improve 13 Reduce the RF generator output until a 12 dB SINAD reading is obta ined 14 Using a non metallic tool slowly tune L801 clockwise or counter clockwise as required f...

Страница 6: ...h 16 Apply 0 95 uV of modulated standard deviation on channel RF signal to the 50 antenna connector Adjust Squelch range RV201 counter clockwise just until squelch opens audio on Figure 2 2 Adjustment...

Страница 7: ...V DC 30 A adjustable voltage 150 W 30 50MHz 50 circuit 50 200 W 30 50 MHz peak responding 5KHz range 30 50 MHz 1 0 ppm accuracy 1 000KHz sine wave 0 4 Vrms output 30 50 MHz range 0 1 1 KuV output 3KHz...