![Midian Electronics VTE-1 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/midian-electronics/vte-1/vte-1_manual_1791965007.webp)
7
JUMPER SETTINGS
The following table shows the default jumper settings and their function:
Jumper
Number
Default Position
Description
JP21
1-2 In – 2-3 Out
De-Emphasis jumper
JP36
1-2 In
Termination jumper
JP40
1-2 In
Termination jumper
JP41
1-2 Out
2175 Hz Pilot Tone Select
JP42
1-2 In
1950 Hz Pilot Tone Select
JP43
1-2 Out
2700 Hz Pilot Tone Select
JP44
1-2 Out
1600 Hz Pilot Tone Select
JP41-JP44
All Out
No Pilot Tone