background image

Thank you for purchasing the MIDI Solutions R8 8-output MIDI-controlled Relay Array.

The MIDI Solutions R8 contains eight MIDI-controlled relays that enable switches or footswitch inputs to be placed
under MIDI control. Each relay can be programmed to respond to a wide variety of MIDI messages, including Note,
Control Change, Program Change, and System Exclusive messages, and programmed settings are retained even
after power is removed from the unit. The MIDI Solutions R8 is MIDI-powered and requires no batteries or power
supply to operate.

INTRODUCTION

To program the R8 connect the MIDI Out from your MIDI interface to the MIDI

of the R8. The MIDI

and

can be left disconnected during programming.

Once the R8 has been programmed it can be inserted wherever it is required in your MIDI setup. Connect the MIDI
Out or Thru of the sending device to the MIDI

of the R8. The

can be made directly to

footswitch inputs or the contacts to be switched. The MIDI

of the R8 can be connected to the MIDI In of a

receiving MIDI device or left disconnected. It is recommended that the number of MIDI Solutions products powered
by a single MIDI Out or Thru be limited to four.

In

Out

Relay

Connections

In

Relay Connections

Out

IMPORTANT: Switching high current or inductive loads can permanently damage the unit, please see the
relay contact ratings at the end of these instructions, and navigate to the following link for more information:
www.midisolutions.com/backemf.htm

CONNECTIONS

3

MIDI Out or Thru

MIDI In

Relay1

Connections

Relay5

Connections

Relay3

Connections

Relay7

Connections

Relay2

Connections

Relay6

Connections

Relay4

Connections

Relay8

Connections

Sending Device

Receiving Device

Содержание PROFESSIONAL Series

Страница 1: ...OPERATING INSTRUCTIONS R8 8 OUTPUT MIDI CONTROLLED RELAY ARRAY PROFESSIONAL SERIES MIDI Solutions ...

Страница 2: ...MIDI Solutions R8 Operating Instructions M426 100 2012 MIDI Solutions Inc All rights reserved MIDI Solutions Inc PO Box 3010 Vancouver BC Canada V6B 3X5 www midisolutions com ...

Страница 3: ...e inserted wherever it is required in your MIDI setup Connect the MIDI Out or Thru of the sending device to the MIDI of the R8 The can be made directly to footswitch inputs or the contacts to be switched The MIDI of the R8 can be connected to the MIDI In of a receiving MIDI device or left disconnected It is recommended that the number of MIDI Solutions products powered by a single MIDI Out or Thru...

Страница 4: ...tings command to the R8 prior to programming the unit to ensure that all previous settings are cleared To dump all of the R8 s current settings send it the following System Exclusive message Upon receipt of this command the R8 will dump its current settings to the MIDI Out To link together the Note and Control Change settings of a specific relay send the R8 the following programming command is set...

Страница 5: ...lay produces OPEN pulse for Note Offs MIDI Note number MIDI channel see MIDI channel table at end Pulse width in 8 ms increments or 1 s increments if preceded by 00 The R8 will accept a combined total of 10 Note or Control Change settings per relay To program the R8 to close Relay6 for 10 seconds when Note On middle C is received on any MIDI channel set Relay6 relay produces CLOSED pulse for Note ...

Страница 6: ...hannel see MIDI channel table at end Threshold value threshold defaults to 64 if this byte omitted Pulse width in 8 ms increments or 1 s increments if preceded by 00 The R8 will accept a combined total of 10 Note or Control Change settings per relay To program the R8 to close Relay2 when the volume on MIDI channel 16 drops below a value of 10 and open when it rises above set Relay2 relay OPEN thre...

Страница 7: ...mand F0 00 00 50 26 03 F7 To program the R8 to respond to Start Stop and Continue messages send it the following System Exclusive programming command is optional All bytes must be in Hexadecimal format see hexadecimal conversion table at end Relay 00 for Relay1 07 for Relay8 is set as follows if is omitted then 00 relay CLOSES for Start Continue OPENS for Stop 01 relay OPENS for Start Continue CLO...

Страница 8: ...y is optional where is the System Exclusive message the relay is being programmed to respond to All bytes must be in Hexadecimal format see hexadecimal conversion table at end Relay 00 for Relay1 07 for Relay8 Pulse width OPEN pulse in 8 ms increments or 1 s increments if preceded by 00 To program the R8 to CLOSE Relay8 when the MIDI Machine Control command F0 7F 7F 06 02 F7 is received and OPEN i...

Страница 9: ...decimal 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 13 14 1F 20 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4F 50 53 54 55 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 77 78 7F Control Function Bank Select Modulation wheel or lever Breath Controller Undefined Foot controller Portamento time Data entry MSB Channel Volume Balance Undefined Pan Expression Controller Effect Controls 1 2 Undefined General ...

Страница 10: ...r no circumstances will MIDI Solutions be liable for any loss of profits benefits time interrupted operation commercial loss or consequential damages arising out of the use or inability to use the product MIDI Solutions specifically disclaims any implied warranties of merchantability and fitness for a particular purpose If the product requires service a Return Merchandise Authorization RMA number ...

Отзывы: