Test Program
No.
Process
0
Intialization
1
Inlet Valve
2
Washing Pump
and Heating
Element
3
Washing Pump
and Dispenser
4
static
5
Drain Pump
6
finish
Procedure of Test Program
(for models controlling water filling by flowmeter)
Dis play on
t he s c reen
05 or
Turbidity
value
03
Description
8:88
Power on, stand by
Open inlet valve and feeds with 1.9L wate
04/Temper-
ature value
Run washing pump and 10s later run heating
element until the water temperature reaches 57℃. Then the
machine will pause.
Press Program button to jump into the next step.
F*
Buzz one sound, stop, and stand by.
washing pump for 10s, dispenser will
act for 45s in this step.
static 30s.
02
01
Drain for 30s.
Running fan closed after 10 seconds
20