7
Removing the c ollected w ater
There are two ways to remove collected water.
1. Use the bucket
When the bucket is full, the unit will automatically
stop running, and the Full indicator light will flash.
Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight so
water does not spill. Do not put the bucket on the floor
because the bottom of the bucket is uneven.
Otherwise the bucket will fall and cause the water
to spill.
Throw away the water and replace the bucket. The
bucket must be in place and securely seated for
the dehumidifier to operate.
The machine will re-start when the bucket is restored
in its correct position.
NOTES:
When you remove the bucket, do not touch any parts
inside of the unit. Doing so may damage the product.
Be sure to push the bucket gently all the way into the
unit. Banging the bucket against anything or failing to
push it in securely may cause the unit not to operate.
2. Continuous draining
Fig.5
Fig.6
Fig.7
1. Pull out the bucket a little.
2. Hold both sides of the bucket
with even strength, and pull it
out from the unit.
3. Pour the water out.
Wate r c an be au t omatically e m ptied in t o a f l o o r
drai n b y atta c h i n g t he un i t w ith a water ho s e
( 12 m m ) (not i n cluded).
NOTE:
When the continuous drain feature is not
being used,remove the drain hose from the outlet
and attach the rubber plug back to the drain outlet.
Remove the rubber plug from the back of the unit and store
it in a safe location.
Insert the water hose into the unit from the drain outlet in the
back of the unit as shown in Fig.8a and Fig.8b. Attach the water
hose to the drain hose outlet of the unit.Make sure the connection
of the water hose and the drain hose outlet of the unit is tight
and do not let the water leak.
Then lead the water hose to the floor drain or a suitable
drainage facility.The drainage facilify should be lower than the
drain outlet of the unit.
Be sure to run the water hose sloping downward and let the
water to flow out smoothly.Do not install the water hose as
shown Fig.9a and Fig.9b.
OPERATING THE UNIT
Fi g . 9 a
Fig.9b
Do not block water flow by a rise.
Do not block water flow by a retortion.
Fig.8a(MODEL A)
Remove the
rubber plug
Insert the water
hose from the
drain outlet
Insert the water
hose from the
drain outlet
Remove the
rubber plug
Fig.8b(MODEL B)