NOTE
Remark per EMC Directive 89/336/EEC
For to prevent flicker impressions during the start of the
compressor (technical process), following installation condi-
tions apply.
The power connection for the air conditioner has to be done
at the main power distribution.The distribution has to be of
a low impedance, normally the required impedance reaches
at a 32A fusing point.
No other equipment has to be connected with this power
line.
For detailed installation acceptance, please refer to your
contract with the power supplier if restrictions do apply for
products like washing machines, air conditioners or
electrical ovens.
●
●
●
2
installation manual
Please refer to the following figure for the distance
measurement between the screw bolts.
Please install with screw bolts.
The handling to the ceiling varies from the constructions, consult
the construction personnels for the specific procedures.
The size of the ceiling to be handled
.
Do keep the ceiling flat. Con-
solidate the roof beam for possible vibration.
Cut off the roof beam.
Strengthen the place cut off, and consolidate the roof beam.
Carry out the pipe and line operation in the ceiling after
finishing the installation of the main body. While choosing where
to start the operation, determine the direction of the pipes to be
drawn out. Especially in case there is a ceiling, position the
refrigerant pipes, drain pipes, indoor & outdoor lines to the connec-
tion places before hanging up the machine.
The installation of hanging screw bolts.
●
●
●
Fig.4-1
Hanging screw bolts
Ceiling
Timber over the beam
Roof beam
Put the square timber traversely overthe roof beam, then
install the hanging screw bolts. (Refer to
Fig.4-1
)
Wooden construction
New concrete bricks
Fig.4-2
Inlaying or embedding the screw bolts (Refer to
Fig.4-2
)
Blade shape insertion
Slide insertion
Installing
Φ
10 Hanging Screw Bolts (4 Bolts)
4. INDOOR UNIT INSTALLATION
Cautions on remote controller installation
Never throw or beat the controller.
Before installation, operate the remote controller to determine
its location in a reception range.
Keep the remote controller at least 1m apart from the nearest
TV set or stereo equipment. (It is necessary to prevent
image disturbances or noise interferences.)
Do not install the remote controller in a place exposed to
direct sunlight or close to a heatingsource, such as a stove.
Note that the positive and negative poles are in right positions
when loading batteries.
●
●
●
●
1. Remote controller....................................1
2. Remote controller holder.........................1
3. Mounting screw
(ST2.9x10-C-H)........................................2
4. Alkaline dry battery(AM4)
..................................................................2
Remote controller & Its Frame
For power details of the air conditioner, refer to the rating
plate of the product.
For any question contact your local dealer.
●
●
Table.3-1
1
1
1
Name of
Accessories
Installation manual
KJR-10B Wire
controller
Pipe insula-
tion material
Adhesive tape for seal
Heat insulation
To connect drain pipe
Q‘ty
4
(This manual)
Outline
Usage
Wire
control the
air-conditioner
Clasp
Network matching wire
1
1
1
Water outlet joint
For drainage
Chucking the joint which
connect the drain hose
and the outlet of indoor
unit
The indoor unit which at
the terminal of
communication system
shouldconnect a
impedance between port
P and port Q
The following are selectable accessories
3. ACCESSORIES
7.1-16.0
20.0-28.0
2
2
3
Remote controller
holder
Mounting screw
Fig.3-1
1
Remote
controller