2
nd
Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual
2.2.2 Display Explanation
TEMP-SET
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
HYBRID MODE
OUTLET TEMP
ECONOMY MODE
HIGH TEMP
FILL WATER
ALARM
LOCK
TIME OFF
TIME ON
TIMER
CONFLICT
E-HEATER MODE
Number Explanation Number
Explanation
1
HIGH TEMP indicator. When the setting temp.
exceeds 50
℃
, it lights up to remind you that the
outlet temp. is too high for direct spray.
9
OUTLET TEMP indicator. It displays water temp.
of the upper part of the tank, which can be used.
It always lights.
2
FILL WATER indicator. When the power supply is
turned on, it lights up to remind you to re-affuse
water.
10
TIMER CONFLICT indicator. When the temp
you set through Wired Controller conflicts with
that through User Interface, it lights up.
3
ALARM indicator: It will flashing at the malfunction
or protection time.
11
TIME OFF indicator: It will light up when timing
off mode is set, blanks when screen
protection.et, blanks when screen protection.
4
TEMP-SET indicator: Show the setting
temperature and blank when screen protection.
Codes are show at the
malfunction or protection time
12
TIME ON indicator: It will light up when timing
on mode is set, blanks when screen
protection.et, blanks when screen protection.
5
LOCK indicator. When the UI is locked, it always
lights.
13
CLOCK indicator. It displays present time, it will
blanks when screen protection
6
Water temp. indicator. When the actual water
temp. exceeds 60
℃
, it lights up.
14
E-HEATER MODE indicator. When user sets the
E-heating Mode, it lights up.
7
Water temp. indicator. When the actual water
temp.exceeds 50
℃
, it lights up.
15
HYBRID MODE indicator. When user sets the
Hybrid Mode, it lights up.
8
Water temp. indicator. When the actual water
temp. exceeds 40
℃
it lights up.
16
ECONOMY MODE indicator. When user set the
Economy Mode, it lights up.
2.2.3 Operation
OFF timer
used to set the
DOWN key,
used to abate
time or temp.
UP key,
used to add
time or temp.
MODE key,
used to set
different modes
CANCEL key,
used to canel
timer and lock
CLOCK key,
used to set
time.
ON\OFF key,
used to turn the
unit on or off
34
Содержание RSJ-35/300RDN3-B
Страница 13: ...2nd Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual ECONOMY MODE Hybrid mode 14...
Страница 14: ...2nd Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual E HEATER MODE 15...
Страница 16: ...2nd Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 4 Dimensions 17...
Страница 19: ...2nd Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 7 Piping Diagrams 20...
Страница 21: ...2nd Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 9 Exploded View 22...
Страница 48: ...2 nd Generation ALL IN ONE Type Heat Pump Water Heater Technical Manual 49 Wiring explanation MCAC R...