3. The selected time will register in 5 seconds
and the air conditioner will automatically
revert back to display the previous temper-
ature setting.
4. Turning the unit ON or OFF at any time
will cancel the Auto Start/stop function.
To cancel the TIMER setting, push
the TIMER button and press or hold the Up
( ) or Down(
) until 0 hour is displayed
on the LCD window of the air conditioner.
NOTE:
1
Swing operation
Use the SWING button to adjust the Left/Right
airflow direction.
1. Pressing this button while the unit is operational
will make the vertical louvers automatically swing
right and left, sweeping the cold/hot air alternately
to obtain comfortable cooling/heating.
2. Press the SWING button again to stop the
swing operation.
Over 50cm
FENCE
AWNING
75
-1
50
cm
Over 50cm
O
About 3~4
FENCE
AWNING
75
-1
50
cm
CAUTION
O
About 3~4
Preferred method of installation into a timber
framed wall, partition or window.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME ALL ROUND
UNIT
TIMBER FRAMED
WALL OR PARTITION
EXTERNAL SUPPORT
FRAME AT BALANCE
POINT OF A/C
ALTERNATIVELY, BRACKETS
AS ILLUSTRATED BELOW
MAY BE USED.
DRAIN PAN
Step 1
Remove the air conditioner from its packaging,
remove fixing screws and slide the air conditioner
out from the housing. (Refer to Installation Steps).
Step 2
Prepare the hole in the wall so that the bottom of the
housing is well supported, the top has minimum
clearance and the air inlet louvers have clearance
as shown below in options A and B. Holes from the
outside through to the cavity should be sealed. The
housing should slope down towards the rear by
about 5mm to allow water formed during operation
to drain.
Step 3
Install the housing into the wall and ensure the foam
seals are not damaged. Seal or fill the gaps around
the inside and outside to provide satisfactory
appearance and protection against the weather,
insects and rodents.
Note: Unit may be supported by a
solid frame from below or by a
hanger from a solid overhead
support.
INSTALLATION INSTRUCTIONS
Select the Best Location
1. To avoid vibration and noise, make sure the units is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly on it.
If the unit receives direct sunlight, build an awning to shade the cabinet.
3. There should be no obstacle, such as a fence or wall within 50 cm from the back
of the cabinet because it will prevent heat radiation on the condenser. Restriction
of outside air will greatly reduce the cooling efficiency of the air conditioner.
4. Install the unit a little obliquely outward so the codensed water will not leak into
the room (about 3~4° with level).
5. Install the unit with its bottom portion 75~150 cm above the floor level.
6. The power cord must be connected to an independent circuit. The yellow/green
wire must be grounded.
All side louvers of the cabinet must remain exposed to the outside of the structure.
Installation of the Housing
13