CONTROL PADS ON THE DEHUMIDIFIER
Control pads
When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.
NOTE: The control panel of the unit you purchased may be slightly different according to the
models.
Fig.1
Humidity Set Control Pads
: Down/Up Pads
TIMER Set Control Pads
Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the pad and set to a lower
percent value(%).
For damper air, press the pad and set a higher
percent value(%).
CONTROL PADS ON THE DEHUMIDIFIER
Other features
Bucket Full Light
Glows wh en the b ucket i s ready to b e
emptied .
Whe n fros t bu ilds up on the evaporator coil s, the
co mpressor wi ll cycle o ff and the fan wi ll conti nue
to run u ntil the fro st d isa ppears.
Auto Defrost
Wait 3 minutes before res uming operation
After the u nit h as stop ped, it can not be re start
ope rtation in the first 3 minute s. Thi s i s to prote ct
the uni t. Operatio n will automatical ly start a fter
3 minu tes.
Setting the Timer
When the unit is on, first pre ss the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is in itiated. Press it aga in the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, the n at 1 hour
increments u p to 24 hours. The co ntrol
will coun t down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within th e same program sequence,
TIMER ON OFF indicato r lights illum inate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at an y time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Sta rt/Stop function
will also be cancelled.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is in itiated. Press it aga in the
Time Off indecator ligh t illuminates.It
indicates the Auto Stop is initiated.
Check filter feature
The system starts to count the time once th e fa n
mo tor op erates. The che ck filter featu re ca n be
onl y a ctivated when the accumulated ope ra tion
time achie ves 250 hours o r mo re . The Reset
light(Clean filter ind icator lig ht) fla she s a t one time
per sec ond, after finis hing cl ean the air fi lter, p ress
the Filte r pad and the Rese t light(Clean filter indi cato r
lig ht) go es off.
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(
5% accuracy) room % humidity level in a range of
- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
±
30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS
Auto Shut Off
The
shu ts
o ff
when
the
buc ket
is
full, or wh en the b ucket is remove d or not re placed
in the prope r position .When the setting h umi dity is
reached, the unit will be shut off au toma tically.
For some model s,the fan mot or will continue
operating .
deh umi difier
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
PUMP Pad(on some models)
Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed
into the unit and the continuous drain hose is removed
from the unit before the pump operation is activated.
When the bucket is full,the pump starts to work.Refer
to the next pages for removing the collected water.
Do not use this operation when the outdoor temperature
is equel to or less than 0 C (32 F).
O
O
POWER Pad
Press to turn the dehumidifier on and off.
TIMER Pad
Press to initiate the Auto start and Auto stop feature,
in conjuction with the and pads.
E3
- Unit malfunction-- Unplug the unit and plug it back in. If
error repeats, call for service.
Eb
- Bucket is removed or not in right position-- Replace the
bucket in the right position.
Auto defrost operation on
indicator light
TIMER
Clean filter
indicator light
Bucket full
indicator light
Pump operation
on indicator light
Continuous
operation on
indicator light
On
Off
Defrost
Full
CONT.
POWER
PUMP
COMFORT
FILTER
TURBO
ION
Timer on/off
indicator light
High fan
indicator light
Ion operation
indicator light
Comfort dehumidifying
operation on
indicator light
TURBO Pad
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
FILTER Pad
The check filter feature is a reminder to clean the
Air Filter for more efficient operation. The Filter
light(Clean filter l ight) will illuminate after 250 hours
of operation. To reset after cleaning the filter, press
the Filter pad and the light will go off.
Press to activate the comfort dehumidifying operation.
NOTE: On this operation,the unit can not be set
humidity level.
COMFORT Pad(optional)
ION Pad(optional)
Press to activate the ionizer. Anions ar automatically
generated by ionization. The anions deactive the
airborne chemical vapors and dust particles. Press
it again to stop the function.
CONTINUE Pad
Press to activate the continuous dehumidifying operation.
- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
- Bucket is full -- Empty the bucket.