104
E7
E8
E9
EE
EH
EH
Ambient temperature
sensor fault
Defrost sensor fault in
variable chamber
High temperature
alarm in freezing
chamber
Circuit fault of ice
maker sensor
Circuit fault of
ambient humidity
sensor
Circuit fault of
ambient humidity
sensor
Step 1:
Check whether the connection terminals are plugged in place
and whether there are foreign matters in them; after cleaning the
terminals, plug them in again.
Step 2:
If the fault still occurs, pull out the corresponding connection
terminal on the main PCB, use a multimeter to check the resistance
value of the sensor, and confirm whether it is normal.
Step 3:
If the resistance value is wrong, replace the sensor.
Step 4:
If the fault still occurs, replace the main PCB.
Step 1:
Check whether the door is not closed, or whether there is
leakage between the door gasket and the cabinet.
Step 2:
Check whether the door gasket is deformed and causes
leakage, reshape or replaced with a new one.
Step 3:
Check whether the freezing frost is OK, if there is ice on the
evaporator and the fan motor is frozen, replace a new defroster
heater.
Step 4:
Check whether the light switch is damaged, replace new one.
Step 5:
Check whether the freezer fan stops working, plug and unplug
connection terminals, replace a new fan motor.
Step 6:
Check if the pipeline is leaking or blocked. After maintenance,
vacuum and refill the refrigerant.
Step 1:
Check whether the connection terminal s on the ice maker
and the main PCB are plugged in place and whether there are
foreign matters in them; after cleaning the terminals, plug them in
again.
Step 2:
If the fault still occurs, pull out the connection terminal on ice
maker, use a multimeter to check the resistance value of the sensor,
and confirm whether it is normal.
Step 3:
If the resistance value is wrong, replace the sensor.
Step 4:
If the fault still occurs, replace the main PCB.
Step 1:
Check whether the connection terminal s in the hinge cover
and the main PCB are plugged in place and whether there are
foreign matters in them; after cleaning the terminals, plug them in
again.
Step 2:
If the fault still occurs, pull out the connection terminal on
the hinge cover, use a multimeter to check the voltage value of the
sensor, and confirm whether it is normal.
Step 3:
If the voltage value is wrong, replace the sensor.
Step 4:
If the fault still occurs, replace the main PCB.
Step 1:
Check whether the water tank is installed in place, pull out the
water tank and install it again;
Step 2:
Check whether the connection terminals behind the water
tank seat is plugged in place and whether there are foreign matters
in it; after cleaning the terminal, plug it in again.
Step 3:
Check whether the switch in the water tank seat is damaged,
replace a new switch.
9.8 Test mode
All below functions are only for diagnosis and test purpose, we advise to restart the refrigerator by power on/off if
have used these functions.
Содержание Olson SBS Series
Страница 5: ...5 1 Notas de actualización importantes ninguna ...
Страница 18: ...18 2 Pegar ubicación Algunos productos también tienen S N en la parte inferior del lado derecho del gabinete ...
Страница 49: ...49 11 1 Sin refrigeración refrigeración por aire electrónica 11 Método de resolución de problemas ...
Страница 50: ...50 ...
Страница 51: ...51 11 2 No funciona el compresor ...
Страница 52: ...52 11 3 Glaseado interior sin descongelar ...
Страница 53: ...53 11 4 Glaseado interior sin descongelación Pautas de mantenimiento ...
Страница 54: ...54 11 5 La luz no está encendida ...
Страница 55: ...55 11 6 Fallo del ventilador 11 7 Circuito de desescarche defectuoso ...
Страница 56: ...56 11 8 Ruido 11 9 Conducto de aire no operado ...
Страница 57: ...57 11 10 La máquina de hielo no produce hielo Opción ...
Страница 58: ...58 11 11 No se cae hielo o hielo picado del distribuidor Opción ...
Страница 63: ...63 1 Significant update notes None ...
Страница 107: ...107 11 1 No cooling Air cooling Electronic 11 Troubleshooting Method ...
Страница 108: ...108 ...
Страница 109: ...109 11 2 No working of compressor ...
Страница 110: ...110 11 3 Inside frosting no defrosting ...
Страница 111: ...111 11 4 Inside frosting no defrosting Maintenance guidelines ...
Страница 112: ...112 11 5 Light is not on ...
Страница 113: ...113 11 6 Fan failure 11 7 Defective defrost circuit ...
Страница 114: ...114 11 8 Noise 11 9 Air duct not operated ...
Страница 115: ...115 11 10 Ice makernot make ice Option ...
Страница 116: ...116 11 11 No ice or crushed ice falling off the distributor Option ...
Страница 117: ......