4.1 Operating Of The Unit
4.2 Leakage Testing
4.3 To Adjust Water Flow
Switch on the power supply, the unit will take self-inspection for 2s, ELCB
green indicator light will be on (under the condition of no electricity leakage).
When the water flow exceeds 1.2L/min, rotate the knob clockwise to switch on
heating power rotate switch, heating indicator light will be on, the unit start to
work.
4. METHODS OF USING
LOW
POWER
ELCB
MAX
OFF
TEST
RESET
When the water heater is working normally, press TEST button, if the leakage
test circuit is no problem, ELCB green indicator light will be off, and the unit will
not heat. Press RESET, testing will be canceled, and ELCB green indicator
light will be on, the unit will be back to working state set before. If the circuit
leaks, press RESET button can’t cancel leakagetesting, “ELCB” and
“POWER” indicator light is twinkling flicker, it means the water heater has
problems and can’t be used; all the buttons are invalid, heating is stopped, and
pump will be closed.
Rotate the handle of water flow adjusting valve to adjust the water flow.
4.4 Electricity Leakage Protection
When the electricity leakage testing circuit is working normally, if the leakage current is bigger than
certain value between 7.5mA and 15mA, the POWER red and ELCB green indicator light will be
off, no heating; it can only be used after the failure is excluded. (When electricity leakage is tested,
“ELCB” and “POWER” indicator light will be twinkling flicker, stop heating )
4.5 To Adjust Water Temperature
NOTE
For first time using, ensure electrify after the unit is filled fully with water and there is
stable water flow comes out from shower head.
The electric water heater may be damaged if the water hardness is too high. To
guarantee the normal service life, please install and put it into use on condition that the
local water hardness is less than 450mg/L (CaCO3).
If the water flow is small and power is high while using the unit, outlet water temperature is rather
high; the unit will stop heating automatically. At this time, please lower the power and adjust the
water flow faster in order to avoid inconsistency of water temperature.
4.6 Use After Overheating Protection
Rotate the handle of water flow adjusting valve to adjust to proper water flow. Adjust power by rotating
knob, clockwise rotate, power will be increased and water temperature increase accordingly or vice
versa.
Содержание MWH-38Q
Страница 12: ...www midea com global...
Страница 24: ...www midea com global Produk ini boleh ditukar tanpa sebarang notis Sila simpan buku panduan ini dengan baik...
Страница 25: ...For Model MWH 38Q...
Страница 26: ...1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10...
Страница 27: ...2 0 450mg L CaCO3 ELCB 3mm 4 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18...
Страница 28: ...3 2 MWH 38Q 240V 50Hz 3800W 16A 2 0mm 20A 0 MPa 2 Liters minute 0 02 MPa 0 3 MPa I IP25 224 330 93 mm 1 2 1 2 2...
Страница 29: ...4 2 3 L N E Relay Relay G E CN1 CN4 CN6 CN2 CN3 CN5 T1 T2 ELCB 3 1 3...
Страница 30: ...5 3 2 1 2 3 4 5 6 60N...
Страница 31: ...6 120 250 180 1 3 3 300mm 6mm 4 1 1 6m 3 4 2...
Страница 32: ...7 2 3 5 OFF 1 2 3 1 2 4...
Страница 34: ...9 4 5 1 2 1 2 450mg L CaCO3 10 1 2 3 4 5 6 5...
Страница 35: ...10 1 2 1 2 1 2 1 2 3 3 3 4 4 1 1 1 2 2 2 1 1 2 2 1 2 ELCB TEMP off ELCB POWER POWER PCB 1 2l min TEMP 6...
Страница 36: ...http www midea com 241000...