background image

2

This water heater is for household, and it can be installed wherever place that need hot water.

Plug is not used for this water heater; this water heater must be connected directly with power 

switch that comes with leakage-protection. Please distinguish live line (red/brown), neutral line 

(blue) and earth line (green/yellow) during installation. 

Do  check  whether  the  amperes  of  the  household  wiring  enough  before  installation,  and 

dedicated circuit must be used when installation.

Before installing this water heater, check and confirm the earth electrode on the socket is reliably 

earthed, without electricity.

The hot water from the water heater may cause scald, please test the temperature of the hot 

water before use.

The distance between water heater installed and water output should be as nearby as possible 

to avoid loss of heat.

The electric water heater may be damaged if the water hardness is too high. To ensure longer 

product lifespan, please install and put it into use on condition that the local water hardness is 

less than 450mg/L (CaCO3)

In  time  of  lightning/thunder,  switch  “Off”  the  Miniature  Circuit  Breaker  (MCB)  in  advance  to 

protect the water heater against possible damage.

Inspection on the built-in ELCB (once a month) to avoid a hazard to users such as damage to 

property, serious injury or death.

Do cut-off power supply before any maintenance. Any maintenance or adjustment towards this 

product by non-professional is highly prohibited.

The damage power cord must be replaced by a good power cord provided by the manufacturer, 

and the replacement should be done by a qualified technician or   engineer  or  professionals  of 

the similar products.

In order to avoid a hazard due to inadvertent resetting of the Earth Leakage Circuit Breaker 

(ELCB), this appliance must not be supplied through an external switching device, such as timer 

or connected to a circuit that is regularly switched “On” and “Off” by the utility.

Water heater is equipped with adjustable flow capacity safety valve. For safety use, please do 

not change its installation location and do not block its water outlet.

For any improper installation and incorrect operation of this product, our company will not be 

liable for any responsibility.

This water heater can be used for other purpose, eg. Washing hands, dishes or foods, and so on. 

(Multi directional water supply is not available).

When  the  shower  is  used  by  someone  such  as  child,  old  person,  sick  person  and  physical 

handicapped  person,  the  concern  person  is  kindly  requested  to  pay  attention  and  check  the 

shower temperature by using hand from time to time.

To prevent personal injury, injury to others and property damage, the instructions below must be 

followed. Incorrect operation due to failure to follow instructions will cause harm or damage.

WARNING

Special Cautions

The water heater should be earthed before use. Please ensure that the resistance of 

household earth wire 

is <4Ω.

 Using water heater without earthed is highly prohibited.

!

1. CAUTIONS

Содержание MWH-38EU3-GR

Страница 1: ...tion Manual For Model Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference The user...

Страница 2: ...e 11 6 Troubleshooting 12 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electric...

Страница 3: ...t towards this product by non professional is highly prohibited The damage power cord must be replaced by a good power cord provided by the manufacturer and the replacement should be done by a qualifi...

Страница 4: ...urrent Dia Of Wire Core Air Switch Rated Pressure Minimum Flow Rate Minimum Pressure Maximum Pressure Protection Class Water Proof Class Products Size Knob Quantity 1 5 Liters minute IP25 3800W 0 16A...

Страница 5: ...GR MWH 38EU3 RS GR Silicon control Flow Sensor Flow Sensor DC pump Water inlet Thermal Terminal Block Terminal Block cut out Main control board Main control board Temperature sensor Temperature senso...

Страница 6: ...trol Board Silicon Control Flow Switch Heating Elements Terminal Block Thermal cut out 3 7 5 1 2 N PE L G T1 T2 8 4 6 N L T1 G N CN1 CN8 CN5 CN6 T1 CN2 CN4 RL1 RL2 CN2 7 CN2 Display Board Main Control...

Страница 7: ...ain Switch Knob and Power Knob to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire p...

Страница 8: ...Drive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cove...

Страница 9: ...ter outlet Do not overexert to avoid damaging the water heater NOTE A private power cord should be used for this unit After connecting to electric network please check the earth condition and make sur...

Страница 10: ...ot heated the outlet water is cold The function icon displayed the water heater is in the morning model the default set temperature 40 C The function icon displayed the water heater is in the night mo...

Страница 11: ...MWH 38EU3 4 4 3 Mode parameter setting Turn on the power water heater initial set temperature 38 rotating knob to adjust temperature temperature allows the adjusting range of 30 to 48 Raise the temper...

Страница 12: ...t from shower head The electric water heater may be damaged if the water hardness is too high To guarantee the normal service life please install and put it into use on condition that the local water...

Страница 13: ...her power is cut 2 Contact authorized service personnel for repair 1 Rotate TEMP knob 2 Repair or replacement the PCB 1 Press the reset handle of the thermal cut out after checking and troubleshooting...

Страница 14: ......

Страница 15: ...asih kerana telah membeli alat pemanas air kami Sila baca buku panduan ini dengan teliti sebelum memasang dan mengendalikan alat pemanas air anda dan disimpan untuk rujukan kelak Pengguna harus menguj...

Страница 16: ...tahui cara cara pemasangan dan penggunaan yang betul bagi memanfaatkan keunggulan prestasinya dengan sepenuhnya Sila simpan buku panduan ini untuk rujukan kelak 1 KANDUNGAN Tajuk mukasurat 1 Amaran 2...

Страница 17: ...ini daripada kerosakan yang mungkin timbul Periksa ELCB pemutus litar bocor ke bumi terbina dalam sekali setiap bulan bagi mengelakkan kebahayaan terhadap pengguna seperti kerosakan harta benda keced...

Страница 18: ...lah 4 Penggunaan alat pemanas air tanpa pembumian adalah dilarang sama sekali 3 2 PENGENALAN PRODUK 2 1 Parameter Prestasi Teknikal Model Voltan Kadaran Frekuensi Kadaran Kuasa Kadaran Arus Kadaran Di...

Страница 19: ...al Blok terminal Papan kawalan utama Papan kawalan utama Tangki Tangki Outlet air Inlet air Outlet air Papan paparan Kawalan Silikon Pemutus termal Panel paparan Struktur Produk untuk MWH 38EU3 GR MWH...

Страница 20: ...8 4 6 N L T1 G N CN1 CN8 CN5 CN6 T1 CN2 CN4 RL1 RL2 CN2 7 CN2 3 5 1 2 N PE L G T1 T2 4 6 N L T1 G N CN1 CN8 CN5 CN6 T1 CN4 RL1 RL2 7 Pemutus termal Blok terminal Elemen pemanasan Suis aliran air Kawa...

Страница 21: ...Tanggalkan skru pada bahagian bawah unit Keluarkan Tombol Suis Utama dan Tombol Kuasa bagi membuat ia tidak terhalang Tanggalkan plat hadapan secara perlahan lahan Hiris lapisan nipis pada jaket kord...

Страница 22: ...aan Tetapkan kedudukan bagi keempat empat batang skru disertakan bersama unit ini tebuk empat lubang yang sedalam plag dinding dengan saiz kepala gerudi yang bersesuian masukkan plag dinding ke dalam...

Страница 23: ...menyalurkan air semula Selaraskan tombol pilihan kuasa pada kedudukan OFF Pilih suis udara dengan perlindungan kebocoran berdasarkan kuasa alat pemanas air Apabila menyambungkan alat pemanas air pada...

Страница 24: ...ak lengkap Ikon fungsi ini dipaparkan bermakna alat pemanas air tidak menjalankan proses pemanasan dan air yang mengalir keluar dari outlet adalah sejuk Ikon fungsi ini dipaparkan bermakna alat pemana...

Страница 25: ...ungsi Tekan butang Ujian untuk membolehkan alat pemanas air melakukan pengesanan litar bocor Tekan butang ini sekali lagi alat pemanas air akan kembali kepada keadaan asal Tekan fungsi Pam untuk mengh...

Страница 26: ...nas air tidak lengkap Sila periksa penyambungan pembumian sebelum penggunaan Ketika ujian kebocoran elektrik berfungsi secara normal jika kebocoran arus elektrik melebihi nilai tertentu iaitu antara 7...

Страница 27: ...CADANGAN Apabila bekalan kuasa dihidupkan skrin memaparkan E5 dan berkelip kelip 1 Kegagaan bekalan kuasa elektrik 2 Kegagalan PCB 3 Berlaku kebocoran arus elektrik 1 Periksa sama ada bekalan kuasa t...

Страница 28: ...Produk ini adalah tertakluk kepada pertukaran tanpa sebarang notis Sila simpan buku panduan ini dengan baik...

Отзывы: