1.  Place unit on floor, a bench or a table. There is a left and right side filler panel; be 

sure to use the proper panel for each side. When installed, the flange for securing 
the panel in place to the window sill will be facing into the room.

A. Hold the side panel in one hand and gently pull back the center to free the open 

end. See Fig. 1.

B.  Slide the free and “I” section of the panel directly into the cabinet as shown in Fig. 2A.

 

Slide the panel down. Be sure to leave enough space to slip the top and bottom of 
the frame into the rails on the cabinet.

How To Install

NOTE

Top rail and side panels at each side are offset to provide the proper pitch to the 
rear of 5/16” (8

mm

). This is necessary for proper condensed water utilization and 

drainage. If you are not using the side panels for any reason, this pitch to the rear 

m

ust be 

m

aintained.

NOTE

For safety reasons, all four (4) screws MUST be securely fastened.

Fig. 1

Fig. F

Fig. F

Fig. G

“I” section

Fig. 2

Fig. 2

C:  Align the hole in the top rail with those in the top of the unit as shown in Fig. F.

D: Secure the top rail to the unit with the 3/8” screws as shown in Fig. G.

Содержание MWA06CR71

Страница 1: ...Before using this product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult wi...

Страница 2: ...he authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intented for use by young children or infirm pers...

Страница 3: ...leakage from another appliance Do not operate or stop the unit by inserting or pulling out the power plug Do not operate with wet hands or in very humid enviroments It may cause electric shock Do not...

Страница 4: ...uld cause injury Do not clean the air conditioner with water Water may enter the unit and degrade the insulation It may cause an electric shock Do not put a pet or house plant where it will be exposed...

Страница 5: ...to the rating when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped wit...

Страница 6: ...ges 4 The power supply cord is now supplying electricity to the unit On some products this it also indicated by a light on the plug head Safety Precautions NOTES Do not use this device to turn the uni...

Страница 7: ...e level Hi Med Lo dB A 56 4 54 1 51 9 58 4 55 8 53 7 59 5 58 5 57 60 5 59 3 57 7 Plug type 5 15P 5 15P 5 15P 5 15P Control type Remote Control Remote Control Remote Control Remote Control Operating te...

Страница 8: ...In front of the unit you may hear the sound of rushing air being moved by the fan High Pitched Chatter Modern compressors may have a high pitched sound during cooling cycle Vibration Unit may vibrate...

Страница 9: ...unit is used in a condition with a relative humidity over 80 there will be condensed water on the surface of the unit Performance may be reduced outside of these operating temperatures Before you beg...

Страница 10: ...omatically to hit the temperature set point you choose In this mode the fan speed cannot be adjusted it starts automatically at a speed according to the room temperature Operating on FAN mode Use this...

Страница 11: ...ress or hold either left or right button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until sta...

Страница 12: ...t from one to the other press and hold the left or right Temp Timer buttons at the same time for 3 seconds The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed See Fig...

Страница 13: ...d rear coils WARNING Before You Begin Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordianaces...

Страница 14: ...foam 1 Top Rail Hardware Top Rail 1 3 8 Screws 4 1 PREPARE THE WINDOW Lower sash must open sufficiently to allow a clear vertical opening H of following size see Table 1 Side louvers and the rear of...

Страница 15: ...panel down Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet How To Install NOTE Top rail and side panels at each side are offset to provide the prop...

Страница 16: ...Once the panel has been installed on the side of the cabinet make sure it sits securely inside the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the top an...

Страница 17: ...d by Storm Window Removing AC From Window Add wood as shown in Fig 10 or remove storm window before air conditioner is installed If storm window frame must remain be sure the drain holes or slots are...

Страница 18: ...t may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or p...

Страница 19: ...cooling but room is too warm NO ice forming on cooling coil behind decorative front Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature...

Страница 20: ...to the indoor unit Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is expo...

Страница 21: ...it b The main unit does not respond to a command issue by the remote control Eletronic Display Protect the remote control from high temperatures and keep away from radiation exposure Keep the control...

Страница 22: ...te the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consu...

Страница 23: ......

Страница 24: ......

Отзывы: