DM12-01.01.02-03en
MIV V4+ Indoor Units
Wall Mounted Type MVW-A-VA1
5
Model MVW56A-VA1
MVW71A-VA1
Power supply
V- Ph-Hz
220-240V~, 1Ph, 50Hz
Cooling
Capacity kW
5.6 7.1
Input W 45
60
Rated current
A
0.2
0.28
Heating
Capacity kW
6.3 8
Input W 45
60
Rated current
A
0.2
0.28
Electrical heating capacity
kW
- -
Indoor fan
motor
Model
YDK18-4 YDK18-4
Type
AC
motor
Brand
Welling
Input W
44/42/39
44/42/39
Capacitor
μ
F 1.2
1.2
Speed (hi/mid/lo)
r/min
980/880/760 980/880/760
Indoor coil
Number of rows
2
2
Tube pitch*row pitch
mm
21 x13.37
21*13.37
Fin spacing
mm
1.5 1.5
Fin type
Hydrophilic
aluminum
Tube outside
diameter and type
mm
Ф
7
Inner groove tube
length *height *width
mm
785*357*26.74
Number of circuits
6
6
Indoor air flow (H/M/L)
m
3
/h
925/860/755 925/860/755
Indoor noise level (Hi/Mid/Lo) dB(A)
40/38/34
40/38/34
Indoor unit
Dimension (W×H×D)
mm
1072×315×230
1072×315×230
Packing (W×H×D)
mm
1180×415×315 1180×415×315
Net/Gross weight
kg
15.1/18.8
15.1/18.8
Refrigerant type
R410A
Throttle
Type
EXV (Mechanical gear modulation, Integrated with the evaporator)
Model EFM-25YGMISZ-6M-A
Design pressure
MPa
4.4/2.6
Refrigerant
piping
Liquid side/ Gas side
mm
Ф
9.53/
Ф
16
Connecting
wiring
Power wiring
mm
2
3*2
Signal wiring
mm
2
3*0.75
Drainage water pipe diameter
OD
Ф
16.5
Controller
Wireless remote controller RM05/BG(T)E-A (Standard), to set address
Operation temp
℃
Cooling
:
17
~
32
;
Heating:10
~
28
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB, 19°CWB, outdoor
temp.:35°CDB,equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.:
7°CDB,6°CWB,equivalent ref. Piping: 8m(horizontal)