background image

Special function 

Air quality is the key to comfort, this air 
conditioner is equipped with Ionizer or
Plasma Dust Collector(Depending on models). 
Ionizer can generate abundant anions to fill
the room with refreshing and nature air. Your 
whole family will enjoy a natural, pure and 
healthy air everyday. The Plasma Dust Collector 
can generate an ionization zone. The air is 
converted to plasma as it passes the high 
voltage ion generator. 95% of the dust, smoke, 
and pollen particles are attracted to the 
electrostatic filter.
 

CLEAN AIR function

Function used after the Shut Down of 
cooling operation to clean the Evaporator 
and keep it as fresh for the next operation. 
This function is easy to be operated as it is 
accessed through the Remote Controller. 
For cooling only models, the unit will 
operate under FAN ONLY mode at LOW 
fan speed for 30 minutes, and then stop 
the operation and the unit turn off.
For cooling & heating models, the unit will 
operate : FAN ONLY mode at Low fan 
speed(13 minutes)--Heating operation 
with LOW fan speed(1 minute)---FAN 
ONLY operation(2 minutes)--
Stop Operation---Turn off the unit. 

Note:

 

This function is only available under 
COOL(AUTO COOL, FORCED COOL)
and DRY mode. 
Before select the function, it is recomm-
ended to run the air conditioner under 
Cooling operation for about half an hour.
Once the Self Clean function is activated, 
all TIMER setting will be cancelled.
During Self Clean  operation, when press 
the SELF CLEAN  button on the remote
controller again  will stop the operation 
and turn off the unit.

 

SELF CLEAN  function

Follow Me function 

To activate the Follow Me feature, point the 
remote control towards the unit and press the 
Follow Me button. T

 If the unit does not receive the 

Follow Me signal during any 7 minute interval,
the unit will beep to indicate the Follow Me  
mode has ended. 

he remote display is actual 

temperature at its location. The remote control 
will send this signal to the air conditioner every
3 minutes interval until press the Follow Me 
button again. 

The remote control serves as a remote 
thermostat allowing for the precise 
temperature control at its location.

OPERATING INSTRUCTIONS

 6

TIMER display

Displayed

 during Timer operation.

CLEAN AIR display(optional)

Displayed when Ionizer or Plasma dust 
collector(depending on models) is activated. 

TURBO operation display

Displayed when select TURBO function 
on cooling operation or on heating 
operation.

DIGITAL DISPLAY 

Displays the current setting temper-
ature when the air conditioner is in 
operation. When SELF CLEAN 
feature is activated, it displays        .

FAN SPEED display

Displayed the selected fan speed: 
AUTO(nothing) and three  fan speed
levels: LOW(    ), MED(        ) and 
HIGH(           ).

,,

, ,

This display is separated into five 
zones. The zones illuminate based on 
the compressor current frequency. For 
example, higher frequency will 
illuminate more zones.

Operation Frequency display

Содержание MSX HRDN1 Series

Страница 1: ...it for future reference Before using your air conditioner please read this manual carefully and keep it for future reference Before using your air conditioner please read this manual carefully and ke...

Страница 2: ...rd is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only...

Страница 3: ...east free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Страница 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Страница 5: ...cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off...

Страница 6: ...l louver 7 Vertical louver 8 Air filter 9 Manual control button 10 Remote controller holder 11 Remote controller 12 Connecting pipe 13 Drain hose 14 Power cord 15 Connecting cable 16 Connective pipe 1...

Страница 7: ...n function is activated all TIMER setting will be cancelled During Self Clean operation when press the SELF CLEAN button on the remote controller again will stop the operation and turn off the unit SE...

Страница 8: ...is used for testing purposes only To restore the remote controller operation use the remote controller directly CAUTION 1 3 2 Mode Cooling operation Heating operation Drying operation Temperature 1 I...

Страница 9: ...horizontal louver will swing up and down automatically To stop the function press the DIRECTION SWING button again The DIRECTION SWING button will be disabled when the air conditioner is not in operat...

Страница 10: ...perature The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used Cool...

Страница 11: ...system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor unit Filter Handle A clogged air filter...

Страница 12: ...to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off Caution 4 Remove the Air Freshening Filt...

Страница 13: ...igh relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air condi...

Страница 14: ...If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit compl...

Страница 15: ...Fuse may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Rep...

Страница 16: ...CS436 U...

Отзывы: