31
9.4.19 Information Inquiry
To enter information inquiry status, complete the following procedure within ten seconds:
Press LED 3 times.
Press SWING 3 times.
If you are successful, you will hear beeps for two seconds.
Use the LED and SWING buttons to cycle through information displayed.
Pressing LED will display the next code in the sequence. Pressing SWING will show the previous.
The table shows information codes. The screen will display this code for two seconds, then the
information for 25 seconds.
Enquiry information
Displaying code
Meaning
T1
T1
T1 temp.
T2
T2
T2 temp.
T3
T3
T3 temp.
T4
T4
T4 temp.
TP
TP
TP temp.
Targeted frequency
FT
Targeted Frequency
Actual frequency
Tr
Actual Frequency
Compressor current
dL
Outdoor AC voltage
Uo
Indoor capacity test
Sn
Reserve
--
Running mode
Outdoor fan speed
Pr
Outdoor fan speed
EXV opening angle
Lr
EXV opening angle
Indoor fan speed
Ir
Indoor fan speed
Indoor humidity
HU
Adjusted setting temperature
TT
Indoor dust concentrations
dT
WIFI signal strength
IF
GA algorithm frequency
oT